Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer

A long multi-channel electrical mobility analyzer (long MCEMA) has been developed and presented for classifying and measuring the size distribution of aerosol particles in the range of 10 to 1000 nm (Intra and Tippayawong, 2009, 2011). In the idealized model, when there are no molecular and no turbu...

Full description

Saved in:
Bibliographic Details
Main Authors: Intra P., Salm J., Tippayawong N.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-84875289819&partnerID=40&md5=0ba94bb190aeb655696f00437800b87d
http://cmuir.cmu.ac.th/handle/6653943832/1617
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-1617
record_format dspace
spelling th-cmuir.6653943832-16172014-08-29T09:29:31Z Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer Intra P. Salm J. Tippayawong N. A long multi-channel electrical mobility analyzer (long MCEMA) has been developed and presented for classifying and measuring the size distribution of aerosol particles in the range of 10 to 1000 nm (Intra and Tippayawong, 2009, 2011). In the idealized model, when there are no molecular and no turbulent diffusion, the charged particles in the MCEMA move along precisely determined trajectories, and the apparatus gives the undistorted mobility spectrum. Here we neglect the effect of the finite width of aerosol inlet channel and of the finite width of the electrometer rings. Practically, however, molecular and turbulent diffusion randomly scatters the trajectories of the particles, giving a smoothed mobility spectrum. The degree of smoothing can be characterized by the resolution. The resolution of the MCEMA can be expressed by an analytical equation because molecular diffusion submits itself relatively well to a theoretical description. Because of the complexity of turbulent diffusion, simplifying assumptions were made for this work. The MCEMA resolution values were calculated based on expected turbulence parameter data. An increase in the inner electrode voltage resulted in an increase in the resolution of the mobility spectrometer. Higher electrometer ring numbers were found to have higher resolution values of the long MCEMA than the lower electrometer ring numbers. The resolution Rd for the electrometer ring number 22 was found to be as high as 150, 280, and 550 for inner electrode voltages of 1, 2, and 3 kV, respectively. The influence of Brownian diffusion on the resolution of the long MCEMA was significant for particles smaller than 100 nm, corresponding to electrometer ring numbers lower than 10. Approximate calculations show that the mobility resolution decreased considerably even with low turbulence in the classifier. © 2013 Copyright Taylor and Francis Group, LLC. 2014-08-29T09:29:31Z 2014-08-29T09:29:31Z 2013 Article 02726351 10.1080/02726351.2012.672543 PTCHD http://www.scopus.com/inward/record.url?eid=2-s2.0-84875289819&partnerID=40&md5=0ba94bb190aeb655696f00437800b87d http://cmuir.cmu.ac.th/handle/6653943832/1617 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description A long multi-channel electrical mobility analyzer (long MCEMA) has been developed and presented for classifying and measuring the size distribution of aerosol particles in the range of 10 to 1000 nm (Intra and Tippayawong, 2009, 2011). In the idealized model, when there are no molecular and no turbulent diffusion, the charged particles in the MCEMA move along precisely determined trajectories, and the apparatus gives the undistorted mobility spectrum. Here we neglect the effect of the finite width of aerosol inlet channel and of the finite width of the electrometer rings. Practically, however, molecular and turbulent diffusion randomly scatters the trajectories of the particles, giving a smoothed mobility spectrum. The degree of smoothing can be characterized by the resolution. The resolution of the MCEMA can be expressed by an analytical equation because molecular diffusion submits itself relatively well to a theoretical description. Because of the complexity of turbulent diffusion, simplifying assumptions were made for this work. The MCEMA resolution values were calculated based on expected turbulence parameter data. An increase in the inner electrode voltage resulted in an increase in the resolution of the mobility spectrometer. Higher electrometer ring numbers were found to have higher resolution values of the long MCEMA than the lower electrometer ring numbers. The resolution Rd for the electrometer ring number 22 was found to be as high as 150, 280, and 550 for inner electrode voltages of 1, 2, and 3 kV, respectively. The influence of Brownian diffusion on the resolution of the long MCEMA was significant for particles smaller than 100 nm, corresponding to electrometer ring numbers lower than 10. Approximate calculations show that the mobility resolution decreased considerably even with low turbulence in the classifier. © 2013 Copyright Taylor and Francis Group, LLC.
format Article
author Intra P.
Salm J.
Tippayawong N.
spellingShingle Intra P.
Salm J.
Tippayawong N.
Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
author_facet Intra P.
Salm J.
Tippayawong N.
author_sort Intra P.
title Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
title_short Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
title_full Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
title_fullStr Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
title_full_unstemmed Influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
title_sort influence of diffusion on the resolution of a multi-channel electrical mobility analyzer
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-84875289819&partnerID=40&md5=0ba94bb190aeb655696f00437800b87d
http://cmuir.cmu.ac.th/handle/6653943832/1617
_version_ 1681419703881302016