Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty
Objective: To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. Material and Method: Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medi...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-33749452699&partnerID=40&md5=21c09e42e18f24a0afe2572b3f0d7e80 http://www.ncbi.nlm.nih.gov/pubmed/17100377 http://cmuir.cmu.ac.th/handle/6653943832/2025 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-2025 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-20252014-08-30T02:00:24Z Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty Silvilairat S. Pongprot Y. Sittiwangkul R. Phornphutkul C. Objective: To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. Material and Method: Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medium-term results were analyzed. The immediate results were classified into two groups based on the pulmonary systolic pressure gradient (PG) immediately after dilation: group I with a PG ≤ 35 mmHg and group II with a PG > 35 mmHg. At medium-term follow-up of 6 to 60 months, echocardiographic evaluations were analyzed and divided into two groups: group A with a PG ≤ 25 mmHg and group B with a PG > 25 mmHg. Demographic characteristics and hemodynamic parameters of immediate and medium-term results were compared and analyzed. Results: Immediately after PBV, the right ventricular systolic pressure (RVSP) decreased from 115.3 □ 37.6 mmHg to 67.0 □ 28.5 mmHg (p < 0.001). The pulmonary systolic pressure gradient decreased from 90.4 □ 37.9 mmHg to 39.3 □ 25.6 mmHg (p < 0.001). Nine of the 25 patients (group II; 36%), with incomplete immediate relief of the obstruction, had more symptoms, a higher baseline PG, higher right atrial pressure, higher RVSP, and a higher systolic pressure ratio. Six of the 25 patients (group B; 24%), with suboptimal medium-term results, had a higher right ventricular voltage on the electrocardiogram, higher pre-dilation PG, and higher RVSP. Conclusion: Successful medium-term outcomes following pulmonary balloon valvuloplasty were achieved in 76% of the patients, with a greater success rate (91%) in patients with a lower right ventricular voltage electrocardiogram (R wave amplitude in V1) ≤ 21 mm, a prevalvuloplasty systolic gradient ≤ 90 mmHg, and right ventricular systolic pressure ≤ 125 mmHg. 2014-08-30T02:00:24Z 2014-08-30T02:00:24Z 2006 Article 01252208 17100377 JMTHB http://www.scopus.com/inward/record.url?eid=2-s2.0-33749452699&partnerID=40&md5=21c09e42e18f24a0afe2572b3f0d7e80 http://www.ncbi.nlm.nih.gov/pubmed/17100377 http://cmuir.cmu.ac.th/handle/6653943832/2025 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Objective: To determine factors influencing immediate and medium-term results of Pulmonary Balloon Valvuloplasty (PBV) for pulmonary valve stenosis. Material and Method: Between 1995 and 2001, the authors carried out PBV in 25 consecutive patients. Two treatment outcomes including immediate and medium-term results were analyzed. The immediate results were classified into two groups based on the pulmonary systolic pressure gradient (PG) immediately after dilation: group I with a PG ≤ 35 mmHg and group II with a PG > 35 mmHg. At medium-term follow-up of 6 to 60 months, echocardiographic evaluations were analyzed and divided into two groups: group A with a PG ≤ 25 mmHg and group B with a PG > 25 mmHg. Demographic characteristics and hemodynamic parameters of immediate and medium-term results were compared and analyzed. Results: Immediately after PBV, the right ventricular systolic pressure (RVSP) decreased from 115.3 □ 37.6 mmHg to 67.0 □ 28.5 mmHg (p < 0.001). The pulmonary systolic pressure gradient decreased from 90.4 □ 37.9 mmHg to 39.3 □ 25.6 mmHg (p < 0.001). Nine of the 25 patients (group II; 36%), with incomplete immediate relief of the obstruction, had more symptoms, a higher baseline PG, higher right atrial pressure, higher RVSP, and a higher systolic pressure ratio. Six of the 25 patients (group B; 24%), with suboptimal medium-term results, had a higher right ventricular voltage on the electrocardiogram, higher pre-dilation PG, and higher RVSP. Conclusion: Successful medium-term outcomes following pulmonary balloon valvuloplasty were achieved in 76% of the patients, with a greater success rate (91%) in patients with a lower right ventricular voltage electrocardiogram (R wave amplitude in V1) ≤ 21 mm, a prevalvuloplasty systolic gradient ≤ 90 mmHg, and right ventricular systolic pressure ≤ 125 mmHg. |
format |
Article |
author |
Silvilairat S. Pongprot Y. Sittiwangkul R. Phornphutkul C. |
spellingShingle |
Silvilairat S. Pongprot Y. Sittiwangkul R. Phornphutkul C. Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
author_facet |
Silvilairat S. Pongprot Y. Sittiwangkul R. Phornphutkul C. |
author_sort |
Silvilairat S. |
title |
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
title_short |
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
title_full |
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
title_fullStr |
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
title_full_unstemmed |
Factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
title_sort |
factors determining immediate and medium-term results after pulmonary balloon valvuloplasty |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-33749452699&partnerID=40&md5=21c09e42e18f24a0afe2572b3f0d7e80 http://www.ncbi.nlm.nih.gov/pubmed/17100377 http://cmuir.cmu.ac.th/handle/6653943832/2025 |
_version_ |
1681419780630773760 |