Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases
This study reports two cases of fracture of the femur with segmental bone loss that were treated by a new technique of bone transport. A minimally invasive plate osteosynthesis (MIPO) bridge from the proximal to distal femur served as a fixation system. A separate Wagner distraction apparatus was us...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-0036291709&partnerID=40&md5=932e9dac29b3cd448f8a854812d72341 http://cmuir.cmu.ac.th/handle/6653943832/2514 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-2514 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-25142014-08-30T02:00:56Z Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases Apivatthakakul T. Arpornchayanon O. This study reports two cases of fracture of the femur with segmental bone loss that were treated by a new technique of bone transport. A minimally invasive plate osteosynthesis (MIPO) bridge from the proximal to distal femur served as a fixation system. A separate Wagner distraction apparatus was used for distraction osteogenesis. After the transport segment docked with the bone fragment, it was fixed to the plate by a percutaneous screw fixation. The Wagner lengthening device was then removed. The total time of external fixation was significantly reduced. A satisfactorily functional result and bone segment regeneration was achieved. The external fixation index was 0.31 and 0.37 month/cm, and the limb length discrepancy was 0.9 and 1.2cm. The advantages of this technique include a decrease in the duration of external fixation, protection against refracture and earlier rehabilitation. © 2002 Elsevier Science Ltd. All rights reserved. 2014-08-30T02:00:56Z 2014-08-30T02:00:56Z 2002 Article 00201383 10.1016/S0020-1383(02)00010-4 12095730 INJUB http://www.scopus.com/inward/record.url?eid=2-s2.0-0036291709&partnerID=40&md5=932e9dac29b3cd448f8a854812d72341 http://cmuir.cmu.ac.th/handle/6653943832/2514 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
This study reports two cases of fracture of the femur with segmental bone loss that were treated by a new technique of bone transport. A minimally invasive plate osteosynthesis (MIPO) bridge from the proximal to distal femur served as a fixation system. A separate Wagner distraction apparatus was used for distraction osteogenesis. After the transport segment docked with the bone fragment, it was fixed to the plate by a percutaneous screw fixation. The Wagner lengthening device was then removed. The total time of external fixation was significantly reduced. A satisfactorily functional result and bone segment regeneration was achieved. The external fixation index was 0.31 and 0.37 month/cm, and the limb length discrepancy was 0.9 and 1.2cm. The advantages of this technique include a decrease in the duration of external fixation, protection against refracture and earlier rehabilitation. © 2002 Elsevier Science Ltd. All rights reserved. |
format |
Article |
author |
Apivatthakakul T. Arpornchayanon O. |
spellingShingle |
Apivatthakakul T. Arpornchayanon O. Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
author_facet |
Apivatthakakul T. Arpornchayanon O. |
author_sort |
Apivatthakakul T. |
title |
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
title_short |
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
title_full |
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
title_fullStr |
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
title_full_unstemmed |
Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects: A new technique of bone transport: A report of two cases |
title_sort |
minimally invasive plate osteosynthesis (mipo) combined with distraction osteogenesis in the treatment of bone defects: a new technique of bone transport: a report of two cases |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-0036291709&partnerID=40&md5=932e9dac29b3cd448f8a854812d72341 http://cmuir.cmu.ac.th/handle/6653943832/2514 |
_version_ |
1681419873102594048 |