Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients
Background: A simple, convenient, and accurate method for detecting urine protein excretion in lupus nephritis is crucial. Objectives: The objectives of the study were to determine the sensitivity and the specificity of the qualitative urine dipstick test value to detect 0.50 g or greater of the qua...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
2014
|
Online Access: | http://www.scopus.com/inward/record.url?eid=2-s2.0-79955072719&partnerID=40&md5=27b9deb50f1df93e0333943e68742998 http://www.ncbi.nlm.nih.gov/pubmed/21441821 http://cmuir.cmu.ac.th/handle/6653943832/2677 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
Language: | English |
id |
th-cmuir.6653943832-2677 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-26772014-08-30T02:25:15Z Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients Chotayaporn T. Kasitanon N. Sukitawut W. Louthrenoo W. Background: A simple, convenient, and accurate method for detecting urine protein excretion in lupus nephritis is crucial. Objectives: The objectives of the study were to determine the sensitivity and the specificity of the qualitative urine dipstick test value to detect 0.50 g or greater of the quantitative 24-hour urine protein (24-hUP) in lupus patients, to evaluate an overall agreement of the dipstick test results and the magnitude of 24-hUP, and to examine the correlation between the spot urine protein creatinine index (S-UPCI) and the 24-hour UPCI with that of the 24-hUp. Methods: A prospective study was conducted in 92 patients with lupus. All dipstick test values from 5 dipstick assays (Bayer, Roche, Meditest USA, Standard Diagnostics, and Arkray) and the S-UPCI were obtained within 6 hours of the 24-hUP collection. Of 149 urine samples, only 39% were collected properly and were used for analysis. Results: The sensitivity and specificity of a ≥2+ dipstick test result to detect 0.50 g or greater 24-hUP were 56-% to 80% and 67% to 92%, respectively. The agreement of the urine dipstick test values and the magnitude of 24-hUP was fair (κ = 0.23-0.32). The correlation between the S-UPCI and the 24-hUP was 0.83 (P < 0.0001), and that of the 24-hour UPCI and the 24-hUP was 1 (P < 0.0001). Using 24-hUP 2 g/d or less, the bias ±1.96 SD of the difference of S-UPCI and 24-hUP was 0.23 (SD, 0.96) g. Conclusions: A ≥2+ dipstick test is relatively sensitive to detect significant proteinuria, but it is poorly correlated with quantitative 24-hUP. The S-UPCI and the 24-hUP can be used interchangeably for follow-up in lupus nephritis patients with proteinuria of less than 2 g/d. Copyright © 2011 Lippincott Williams & Wilkins. 2014-08-30T02:25:15Z 2014-08-30T02:25:15Z 2011 Article 10761608 10.1097/RHU.0b013e318214bd18 21441821 JCRHF http://www.scopus.com/inward/record.url?eid=2-s2.0-79955072719&partnerID=40&md5=27b9deb50f1df93e0333943e68742998 http://www.ncbi.nlm.nih.gov/pubmed/21441821 http://cmuir.cmu.ac.th/handle/6653943832/2677 English |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
language |
English |
description |
Background: A simple, convenient, and accurate method for detecting urine protein excretion in lupus nephritis is crucial. Objectives: The objectives of the study were to determine the sensitivity and the specificity of the qualitative urine dipstick test value to detect 0.50 g or greater of the quantitative 24-hour urine protein (24-hUP) in lupus patients, to evaluate an overall agreement of the dipstick test results and the magnitude of 24-hUP, and to examine the correlation between the spot urine protein creatinine index (S-UPCI) and the 24-hour UPCI with that of the 24-hUp. Methods: A prospective study was conducted in 92 patients with lupus. All dipstick test values from 5 dipstick assays (Bayer, Roche, Meditest USA, Standard Diagnostics, and Arkray) and the S-UPCI were obtained within 6 hours of the 24-hUP collection. Of 149 urine samples, only 39% were collected properly and were used for analysis. Results: The sensitivity and specificity of a ≥2+ dipstick test result to detect 0.50 g or greater 24-hUP were 56-% to 80% and 67% to 92%, respectively. The agreement of the urine dipstick test values and the magnitude of 24-hUP was fair (κ = 0.23-0.32). The correlation between the S-UPCI and the 24-hUP was 0.83 (P < 0.0001), and that of the 24-hour UPCI and the 24-hUP was 1 (P < 0.0001). Using 24-hUP 2 g/d or less, the bias ±1.96 SD of the difference of S-UPCI and 24-hUP was 0.23 (SD, 0.96) g. Conclusions: A ≥2+ dipstick test is relatively sensitive to detect significant proteinuria, but it is poorly correlated with quantitative 24-hUP. The S-UPCI and the 24-hUP can be used interchangeably for follow-up in lupus nephritis patients with proteinuria of less than 2 g/d. Copyright © 2011 Lippincott Williams & Wilkins. |
format |
Article |
author |
Chotayaporn T. Kasitanon N. Sukitawut W. Louthrenoo W. |
spellingShingle |
Chotayaporn T. Kasitanon N. Sukitawut W. Louthrenoo W. Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
author_facet |
Chotayaporn T. Kasitanon N. Sukitawut W. Louthrenoo W. |
author_sort |
Chotayaporn T. |
title |
Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
title_short |
Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
title_full |
Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
title_fullStr |
Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
title_full_unstemmed |
Comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
title_sort |
comparison of proteinuria determination by urine dipstick, spot urine protein creatinine index, and urine protein 24 hours in lupus patients |
publishDate |
2014 |
url |
http://www.scopus.com/inward/record.url?eid=2-s2.0-79955072719&partnerID=40&md5=27b9deb50f1df93e0333943e68742998 http://www.ncbi.nlm.nih.gov/pubmed/21441821 http://cmuir.cmu.ac.th/handle/6653943832/2677 |
_version_ |
1681419903964282880 |