Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias

Using a mouse monoclonal antibody (mAb) ("2D4") with high specific reactivity to Hb Bart's and a rabbit polyclonal antibody ("RPB") with high reactivity to Hb Bart's but low reactivity to HbF, an ELISA assay was developed for the quantification of Hb Bart's in hemo...

Full description

Saved in:
Bibliographic Details
Main Authors: Makonkawkeyoon L., Pharephan S., Tuntiwechapikul W., Makonkawkeyoon S.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-76549136256&partnerID=40&md5=46ec0c741186cca409f84e1f2fe800fc
http://cmuir.cmu.ac.th/handle/6653943832/2841
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-2841
record_format dspace
spelling th-cmuir.6653943832-28412014-08-30T02:25:27Z Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias Makonkawkeyoon L. Pharephan S. Tuntiwechapikul W. Makonkawkeyoon S. Using a mouse monoclonal antibody (mAb) ("2D4") with high specific reactivity to Hb Bart's and a rabbit polyclonal antibody ("RPB") with high reactivity to Hb Bart's but low reactivity to HbF, an ELISA assay was developed for the quantification of Hb Bart's in hemolysates of peripheral blood. In the preliminary study, hemoglobin solutions containing 4,000 μg/mL of hemoglobin were analyzed for the concentration of Hb Bart's in samples collected from the following children and adult subjects of HbH families: 12 children with deletional HbH disease (--/-α3.7) or nondeletional HbH disease (HbH disease with HbCS) (--/α csα), 12 adults with α0 thalassemia (--/αα), 12 adults with deletional or nondeletional α+ thalassemia (-α3.7/αα or αα/αcsα) and 12 normal adult subjects (αα/αα). The mean ± S.D. of Hb Bart's concentration in those with deletional HbH disease or HbH disease with HbCS, α0 thalassemia, deletional or nondeletional α+ thalassemia, and normal subjects were 1,374±210 (range 1,164-1,584), 1,118±357 (range 761-1,475), 451 ± 230 (range 221-681), and 0 ng/mL, respectively. When the developed ELISA was further evaluated with additional samples of various types of α thalassemia, including: 18 with deletional HbH disease (--/-α3.7); 21 of nondeletional HbH disease (HbH disease with HbCS) (--/αcsα); 33 with α0 thalassemia (--/αα); 19 with nondeletional α+ thalassemia (αα/αcsα); 11 with deletional α+ thalassemia (-α3.7/ αα) and 58 normal subjects (αα/αα). It was found that the levels of Hb Bart's in deletional α+ thalassemia was significantly lower than in α0 thalassemia (p<0.001). The levels of Hb Bart's in α0 thalassemia was also significantly lower than in nondeletional and deletional HbH diseases (p=0.023 and p<0.001, respectively). When all types of α thalassemia were compared with normal subjects, the Hb Bart's levels in all types of α thalassemia were significantly higher (p<0.0001). All of our results indicated that the developed ELISA was highly sensitive and specific for quantitative determination of Hb Bart's in hemolysates. The ELISA assay might be used as a rapid screening test for the detection of α thalassemias in general population. © Makonkawkeyoon et al. 2014-08-30T02:25:27Z 2014-08-30T02:25:27Z 2009 Article 18742769 10.2174/1874276900903010011 http://www.scopus.com/inward/record.url?eid=2-s2.0-76549136256&partnerID=40&md5=46ec0c741186cca409f84e1f2fe800fc http://cmuir.cmu.ac.th/handle/6653943832/2841 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Using a mouse monoclonal antibody (mAb) ("2D4") with high specific reactivity to Hb Bart's and a rabbit polyclonal antibody ("RPB") with high reactivity to Hb Bart's but low reactivity to HbF, an ELISA assay was developed for the quantification of Hb Bart's in hemolysates of peripheral blood. In the preliminary study, hemoglobin solutions containing 4,000 μg/mL of hemoglobin were analyzed for the concentration of Hb Bart's in samples collected from the following children and adult subjects of HbH families: 12 children with deletional HbH disease (--/-α3.7) or nondeletional HbH disease (HbH disease with HbCS) (--/α csα), 12 adults with α0 thalassemia (--/αα), 12 adults with deletional or nondeletional α+ thalassemia (-α3.7/αα or αα/αcsα) and 12 normal adult subjects (αα/αα). The mean ± S.D. of Hb Bart's concentration in those with deletional HbH disease or HbH disease with HbCS, α0 thalassemia, deletional or nondeletional α+ thalassemia, and normal subjects were 1,374±210 (range 1,164-1,584), 1,118±357 (range 761-1,475), 451 ± 230 (range 221-681), and 0 ng/mL, respectively. When the developed ELISA was further evaluated with additional samples of various types of α thalassemia, including: 18 with deletional HbH disease (--/-α3.7); 21 of nondeletional HbH disease (HbH disease with HbCS) (--/αcsα); 33 with α0 thalassemia (--/αα); 19 with nondeletional α+ thalassemia (αα/αcsα); 11 with deletional α+ thalassemia (-α3.7/ αα) and 58 normal subjects (αα/αα). It was found that the levels of Hb Bart's in deletional α+ thalassemia was significantly lower than in α0 thalassemia (p<0.001). The levels of Hb Bart's in α0 thalassemia was also significantly lower than in nondeletional and deletional HbH diseases (p=0.023 and p<0.001, respectively). When all types of α thalassemia were compared with normal subjects, the Hb Bart's levels in all types of α thalassemia were significantly higher (p<0.0001). All of our results indicated that the developed ELISA was highly sensitive and specific for quantitative determination of Hb Bart's in hemolysates. The ELISA assay might be used as a rapid screening test for the detection of α thalassemias in general population. © Makonkawkeyoon et al.
format Article
author Makonkawkeyoon L.
Pharephan S.
Tuntiwechapikul W.
Makonkawkeyoon S.
spellingShingle Makonkawkeyoon L.
Pharephan S.
Tuntiwechapikul W.
Makonkawkeyoon S.
Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
author_facet Makonkawkeyoon L.
Pharephan S.
Tuntiwechapikul W.
Makonkawkeyoon S.
author_sort Makonkawkeyoon L.
title Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
title_short Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
title_full Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
title_fullStr Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
title_full_unstemmed Application of monoclonal and polyclonal antibodies to Hb Bart's for the detection of α thalassemias
title_sort application of monoclonal and polyclonal antibodies to hb bart's for the detection of α thalassemias
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-76549136256&partnerID=40&md5=46ec0c741186cca409f84e1f2fe800fc
http://cmuir.cmu.ac.th/handle/6653943832/2841
_version_ 1681419935382765568