Insulation level and clearances for 230 kV air insulated substation

This paper analyzes the insulation level and air clearances of 230 kV air insulated substation. In order to get the BIL, the crest voltage at any equipment are required. By applying simplified calculation method taken from IEEE Std. 1313.2-1999 and IEEE Std. 1427-2006 compared with digital simulatio...

Full description

Saved in:
Bibliographic Details
Main Author: Thanasaksiri T.
Format: Conference or Workshop Item
Language:English
Published: IEEE Computer Society 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-84905405566&partnerID=40&md5=92ffccafef78427f16c1dd23bb610b78
http://cmuir.cmu.ac.th/handle/6653943832/37581
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-37581
record_format dspace
spelling th-cmuir.6653943832-375812014-12-09T05:49:24Z Insulation level and clearances for 230 kV air insulated substation Thanasaksiri T. This paper analyzes the insulation level and air clearances of 230 kV air insulated substation. In order to get the BIL, the crest voltage at any equipment are required. By applying simplified calculation method taken from IEEE Std. 1313.2-1999 and IEEE Std. 1427-2006 compared with digital simulation. The simulations have been implemented using simplified models via EMTP-ATP. The BIL required and BIL selected from simplified calculation may give the insulation level not in the range, so the digital simulation would be the better choice. The effect of elevation from sea level as well as the switching surge have been considered for insulation levels and clearances. © 2014 IEEE. 2014-12-09T05:49:24Z 2014-12-09T05:49:24Z 2014 Conference Paper 9781479929924 10.1109/ECTICon.2014.6839736 106689 http://www.scopus.com/inward/record.url?eid=2-s2.0-84905405566&partnerID=40&md5=92ffccafef78427f16c1dd23bb610b78 http://cmuir.cmu.ac.th/handle/6653943832/37581 English IEEE Computer Society
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description This paper analyzes the insulation level and air clearances of 230 kV air insulated substation. In order to get the BIL, the crest voltage at any equipment are required. By applying simplified calculation method taken from IEEE Std. 1313.2-1999 and IEEE Std. 1427-2006 compared with digital simulation. The simulations have been implemented using simplified models via EMTP-ATP. The BIL required and BIL selected from simplified calculation may give the insulation level not in the range, so the digital simulation would be the better choice. The effect of elevation from sea level as well as the switching surge have been considered for insulation levels and clearances. © 2014 IEEE.
format Conference or Workshop Item
author Thanasaksiri T.
spellingShingle Thanasaksiri T.
Insulation level and clearances for 230 kV air insulated substation
author_facet Thanasaksiri T.
author_sort Thanasaksiri T.
title Insulation level and clearances for 230 kV air insulated substation
title_short Insulation level and clearances for 230 kV air insulated substation
title_full Insulation level and clearances for 230 kV air insulated substation
title_fullStr Insulation level and clearances for 230 kV air insulated substation
title_full_unstemmed Insulation level and clearances for 230 kV air insulated substation
title_sort insulation level and clearances for 230 kv air insulated substation
publisher IEEE Computer Society
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-84905405566&partnerID=40&md5=92ffccafef78427f16c1dd23bb610b78
http://cmuir.cmu.ac.th/handle/6653943832/37581
_version_ 1681421372623945728