Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy
The purpose of this study was to compare the sample preparation for detection of the corn seed infected with Aspergillus flavus by NIR (near infrared) spectroscopy. There were two kinds of samples: whole grain corn, and ground corn seed. The spectra of non-infected (normal seed) and infected seeds a...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Chiang Mai University
2015
|
Subjects: | |
Online Access: | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84872230891&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38038 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-38038 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-380382015-06-16T04:14:35Z Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy Phetkaeo T. Phetkaeo T. Phetkaeo T. Klaithin R. Klaithin R. Theanjumpol P. Theanjumpol P. Kunasakdakul K. Kunasakdakul K. Kunasakdakul K. Thanapornpoonpong S. Thanapornpoonpong S. Thanapornpoonpong S. Vearasilp S. Vearasilp S. Vearasilp S. Multidisciplinary The purpose of this study was to compare the sample preparation for detection of the corn seed infected with Aspergillus flavus by NIR (near infrared) spectroscopy. There were two kinds of samples: whole grain corn, and ground corn seed. The spectra of non-infected (normal seed) and infected seeds at the ratio of 5, 10, 15 and 20% w/w were scanned by using NIRSystem 6500 in the wavelength range 1100-2500 nm. The ground sample was prepared by laboratory mill, then its spectrum was scanned using the same process as the whole infected grain. The mathematical techniques such as second derivative, multiplicative scatter correction and second derivative were used to transform the NIR spectra. The calibration equations to predict the infected quantity of infected seeds of whole grain and ground samples were developed by partial least squares regression (PLSR). It was found that the calibration equation for the infected seed prediction of ground sample provided the higher value of the correlation coefficient (R) and ratio of standard deviation of reference data in validation set to SEP (RPD) than whole grain samples which were 0.98, 5.36 and 0.80, 1.74 respectively. Meanwhile, the standard errors of calibration (SEC), the standard errors of prediction (SEP) and the averages of difference between actual and NIR values (Bias) of ground sample were lower than those from whole grain sample. There were 4.18, 4.08, 0.54% and 1.17, 1.32, 0.38% respectively. Therefore, ground sample is suggested before subject to NIR spectroscopy to detect the infected maize seed. 2015-06-16T04:14:35Z 2015-06-16T04:14:35Z 2012-12-01 Article 16851994 2-s2.0-84872230891 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84872230891&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38038 Chiang Mai University |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Multidisciplinary |
spellingShingle |
Multidisciplinary Phetkaeo T. Phetkaeo T. Phetkaeo T. Klaithin R. Klaithin R. Theanjumpol P. Theanjumpol P. Kunasakdakul K. Kunasakdakul K. Kunasakdakul K. Thanapornpoonpong S. Thanapornpoonpong S. Thanapornpoonpong S. Vearasilp S. Vearasilp S. Vearasilp S. Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
description |
The purpose of this study was to compare the sample preparation for detection of the corn seed infected with Aspergillus flavus by NIR (near infrared) spectroscopy. There were two kinds of samples: whole grain corn, and ground corn seed. The spectra of non-infected (normal seed) and infected seeds at the ratio of 5, 10, 15 and 20% w/w were scanned by using NIRSystem 6500 in the wavelength range 1100-2500 nm. The ground sample was prepared by laboratory mill, then its spectrum was scanned using the same process as the whole infected grain. The mathematical techniques such as second derivative, multiplicative scatter correction and second derivative were used to transform the NIR spectra. The calibration equations to predict the infected quantity of infected seeds of whole grain and ground samples were developed by partial least squares regression (PLSR). It was found that the calibration equation for the infected seed prediction of ground sample provided the higher value of the correlation coefficient (R) and ratio of standard deviation of reference data in validation set to SEP (RPD) than whole grain samples which were 0.98, 5.36 and 0.80, 1.74 respectively. Meanwhile, the standard errors of calibration (SEC), the standard errors of prediction (SEP) and the averages of difference between actual and NIR values (Bias) of ground sample were lower than those from whole grain sample. There were 4.18, 4.08, 0.54% and 1.17, 1.32, 0.38% respectively. Therefore, ground sample is suggested before subject to NIR spectroscopy to detect the infected maize seed. |
format |
Article |
author |
Phetkaeo T. Phetkaeo T. Phetkaeo T. Klaithin R. Klaithin R. Theanjumpol P. Theanjumpol P. Kunasakdakul K. Kunasakdakul K. Kunasakdakul K. Thanapornpoonpong S. Thanapornpoonpong S. Thanapornpoonpong S. Vearasilp S. Vearasilp S. Vearasilp S. |
author_facet |
Phetkaeo T. Phetkaeo T. Phetkaeo T. Klaithin R. Klaithin R. Theanjumpol P. Theanjumpol P. Kunasakdakul K. Kunasakdakul K. Kunasakdakul K. Thanapornpoonpong S. Thanapornpoonpong S. Thanapornpoonpong S. Vearasilp S. Vearasilp S. Vearasilp S. |
author_sort |
Phetkaeo T. |
title |
Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
title_short |
Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
title_full |
Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
title_fullStr |
Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
title_full_unstemmed |
Comparison of sample preparation methods on the infected corn seed detection by NIR spectroscopy |
title_sort |
comparison of sample preparation methods on the infected corn seed detection by nir spectroscopy |
publisher |
Chiang Mai University |
publishDate |
2015 |
url |
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84872230891&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38038 |
_version_ |
1681421400564301824 |