Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure
Background: Intraocular pressure (IOP) is the most important risk factor in glaucoma. Before each measurement, anesthetic eye drop must be applied. The effect of these eye drops may affect the central corneal thickness (CCT) and the IOP. Objective: We investigated the effect of 0.5% tetracaine hydro...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
IOS Press
2015
|
Subjects: | |
Online Access: | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84871835199&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38242 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-38242 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-382422015-06-16T07:46:43Z Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure Manassakorn,A. Chaidaroon,W. Medicine (all) Biochemistry, Genetics and Molecular Biology (all) Background: Intraocular pressure (IOP) is the most important risk factor in glaucoma. Before each measurement, anesthetic eye drop must be applied. The effect of these eye drops may affect the central corneal thickness (CCT) and the IOP. Objective: We investigated the effect of 0.5% tetracaine hydrochloride on central CCT and IOP in glaucoma patients. Methods: Glaucoma subjects aged ≥18 years, with spherical refractive error <±6 diopters(D) and astigmatism ≤3D were included. All underwent CCT and IOP measurement using Orbscan II and air-puff tonometer at baseline, and 1, 3, 5, 7, 9, 11, 13, and 15 minutes after application of 0.5% tetracaine hydrochloride. Results: There were 19 and 24 eyes eligible for CCT and IOP measurements. The mean±SD ages were 62.7±8.2 and 62.9±8.3 years. The mean±SD CCT at baseline was 527.8±32.2 μm. The mean±SD IOP at baseline was 13.2±5.6 mmHg. Although CCT did not change from baseline (p = 0.071), IOP significantly decreased from baseline at three, seven, and 11 minutes (p = 0.003, <0.001, and 0.002). Conclusions: CCT and IOP change trends were different. Although IOP decreased from baseline, CCT was unchanged. 2015-06-16T07:46:43Z 2015-06-16T07:46:43Z 2012-04-01 Article 19057415 2-s2.0-84871835199 10.5372/1905-7415.0602.056 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84871835199&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38242 IOS Press |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Medicine (all) Biochemistry, Genetics and Molecular Biology (all) |
spellingShingle |
Medicine (all) Biochemistry, Genetics and Molecular Biology (all) Manassakorn,A. Chaidaroon,W. Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
description |
Background: Intraocular pressure (IOP) is the most important risk factor in glaucoma. Before each measurement, anesthetic eye drop must be applied. The effect of these eye drops may affect the central corneal thickness (CCT) and the IOP. Objective: We investigated the effect of 0.5% tetracaine hydrochloride on central CCT and IOP in glaucoma patients. Methods: Glaucoma subjects aged ≥18 years, with spherical refractive error <±6 diopters(D) and astigmatism ≤3D were included. All underwent CCT and IOP measurement using Orbscan II and air-puff tonometer at baseline, and 1, 3, 5, 7, 9, 11, 13, and 15 minutes after application of 0.5% tetracaine hydrochloride. Results: There were 19 and 24 eyes eligible for CCT and IOP measurements. The mean±SD ages were 62.7±8.2 and 62.9±8.3 years. The mean±SD CCT at baseline was 527.8±32.2 μm. The mean±SD IOP at baseline was 13.2±5.6 mmHg. Although CCT did not change from baseline (p = 0.071), IOP significantly decreased from baseline at three, seven, and 11 minutes (p = 0.003, <0.001, and 0.002). Conclusions: CCT and IOP change trends were different. Although IOP decreased from baseline, CCT was unchanged. |
format |
Article |
author |
Manassakorn,A. Chaidaroon,W. |
author_facet |
Manassakorn,A. Chaidaroon,W. |
author_sort |
Manassakorn,A. |
title |
Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
title_short |
Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
title_full |
Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
title_fullStr |
Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
title_full_unstemmed |
Effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
title_sort |
effects of 0.5% tetracaine hydrochloride on central corneal thickness and intraocular pressure |
publisher |
IOS Press |
publishDate |
2015 |
url |
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84871835199&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38242 |
_version_ |
1681421437987979264 |