A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer

© 2015 The Author. The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our...

Full description

Saved in:
Bibliographic Details
Main Authors: Chitapanarux I., Tharavichitkul E., Nobnop W., Wanwilairat S., Vongtama R., Traisathit P.
Format: Article
Published: Japan Radiation Research Society 2015
Subjects:
Online Access:http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84929926521&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38506
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-38506
record_format dspace
spelling th-cmuir.6653943832-385062015-06-16T07:47:22Z A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer Chitapanarux I. Tharavichitkul E. Nobnop W. Wanwilairat S. Vongtama R. Traisathit P. Health, Toxicology and Mutagenesis Radiology, Nuclear Medicine and Imaging Radiation © 2015 The Author. The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT. 2015-06-16T07:47:22Z 2015-06-16T07:47:22Z 2015-01-01 Article 04493060 2-s2.0-84929926521 10.1093/jrr/rrv004 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84929926521&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38506 Japan Radiation Research Society
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Health, Toxicology and Mutagenesis
Radiology, Nuclear Medicine and Imaging
Radiation
spellingShingle Health, Toxicology and Mutagenesis
Radiology, Nuclear Medicine and Imaging
Radiation
Chitapanarux I.
Tharavichitkul E.
Nobnop W.
Wanwilairat S.
Vongtama R.
Traisathit P.
A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
description © 2015 The Author. The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT.
format Article
author Chitapanarux I.
Tharavichitkul E.
Nobnop W.
Wanwilairat S.
Vongtama R.
Traisathit P.
author_facet Chitapanarux I.
Tharavichitkul E.
Nobnop W.
Wanwilairat S.
Vongtama R.
Traisathit P.
author_sort Chitapanarux I.
title A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_short A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_full A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_fullStr A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_full_unstemmed A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_sort comparative planning study of step-and-shoot imrt versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
publisher Japan Radiation Research Society
publishDate 2015
url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84929926521&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38506
_version_ 1681421485961379840