Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
© 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were o...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Elsevier
2015
|
Subjects: | |
Online Access: | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38818 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-38818 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-388182015-06-16T07:54:18Z Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis Ponhong,K. Teshima,N. Grudpan,K. Vichapong,J. Motomizu,S. Sakai,T. Chemistry (all) © 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were optimized for the enhancement of successive analytical performances. The interferences from urine matrices on the determination of bilirubin and creatinine were eliminated to dilute urine samples. The calibration graphs with the optimum conditions were achieved to be in 0.024-5.0 mg L-1 for bilirubin and 2-100 mg L-1 for creatinine. The relative standard deviations (RSDs) at 3 mg L-1 of bilirubin and at 50 mg L-1 of creatinine for 11 runs were 1.5 and 1.0%, respectively. The limits of detections (3σ of blank) for bilirubin and creatinine were 7 μg L-1 and 0.6 mg L-1, respectively. The sample throughput for stepwise detection was 22 h-1. The proposed method was applied to the successive determination of bilirubin and creatinine in urine samples. 2015-06-16T07:54:18Z 2015-06-16T07:54:18Z 2015-01-01 Article 00399140 2-s2.0-84913556171 10.1016/j.talanta.2014.05.065 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38818 Elsevier |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Chemistry (all) |
spellingShingle |
Chemistry (all) Ponhong,K. Teshima,N. Grudpan,K. Vichapong,J. Motomizu,S. Sakai,T. Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
description |
© 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were optimized for the enhancement of successive analytical performances. The interferences from urine matrices on the determination of bilirubin and creatinine were eliminated to dilute urine samples. The calibration graphs with the optimum conditions were achieved to be in 0.024-5.0 mg L-1 for bilirubin and 2-100 mg L-1 for creatinine. The relative standard deviations (RSDs) at 3 mg L-1 of bilirubin and at 50 mg L-1 of creatinine for 11 runs were 1.5 and 1.0%, respectively. The limits of detections (3σ of blank) for bilirubin and creatinine were 7 μg L-1 and 0.6 mg L-1, respectively. The sample throughput for stepwise detection was 22 h-1. The proposed method was applied to the successive determination of bilirubin and creatinine in urine samples. |
format |
Article |
author |
Ponhong,K. Teshima,N. Grudpan,K. Vichapong,J. Motomizu,S. Sakai,T. |
author_facet |
Ponhong,K. Teshima,N. Grudpan,K. Vichapong,J. Motomizu,S. Sakai,T. |
author_sort |
Ponhong,K. |
title |
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
title_short |
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
title_full |
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
title_fullStr |
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
title_full_unstemmed |
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
title_sort |
successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis |
publisher |
Elsevier |
publishDate |
2015 |
url |
http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38818 |
_version_ |
1681421542458654720 |