Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis

© 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were o...

Full description

Saved in:
Bibliographic Details
Main Authors: Ponhong,K., Teshima,N., Grudpan,K., Vichapong,J., Motomizu,S., Sakai,T.
Format: Article
Published: Elsevier 2015
Subjects:
Online Access:http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38818
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-38818
record_format dspace
spelling th-cmuir.6653943832-388182015-06-16T07:54:18Z Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis Ponhong,K. Teshima,N. Grudpan,K. Vichapong,J. Motomizu,S. Sakai,T. Chemistry (all) © 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were optimized for the enhancement of successive analytical performances. The interferences from urine matrices on the determination of bilirubin and creatinine were eliminated to dilute urine samples. The calibration graphs with the optimum conditions were achieved to be in 0.024-5.0 mg L-1 for bilirubin and 2-100 mg L-1 for creatinine. The relative standard deviations (RSDs) at 3 mg L-1 of bilirubin and at 50 mg L-1 of creatinine for 11 runs were 1.5 and 1.0%, respectively. The limits of detections (3σ of blank) for bilirubin and creatinine were 7 μg L-1 and 0.6 mg L-1, respectively. The sample throughput for stepwise detection was 22 h-1. The proposed method was applied to the successive determination of bilirubin and creatinine in urine samples. 2015-06-16T07:54:18Z 2015-06-16T07:54:18Z 2015-01-01 Article 00399140 2-s2.0-84913556171 10.1016/j.talanta.2014.05.065 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38818 Elsevier
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Chemistry (all)
spellingShingle Chemistry (all)
Ponhong,K.
Teshima,N.
Grudpan,K.
Vichapong,J.
Motomizu,S.
Sakai,T.
Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
description © 2014 Elsevier B.V. All rights reserved. A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were optimized for the enhancement of successive analytical performances. The interferences from urine matrices on the determination of bilirubin and creatinine were eliminated to dilute urine samples. The calibration graphs with the optimum conditions were achieved to be in 0.024-5.0 mg L-1 for bilirubin and 2-100 mg L-1 for creatinine. The relative standard deviations (RSDs) at 3 mg L-1 of bilirubin and at 50 mg L-1 of creatinine for 11 runs were 1.5 and 1.0%, respectively. The limits of detections (3σ of blank) for bilirubin and creatinine were 7 μg L-1 and 0.6 mg L-1, respectively. The sample throughput for stepwise detection was 22 h-1. The proposed method was applied to the successive determination of bilirubin and creatinine in urine samples.
format Article
author Ponhong,K.
Teshima,N.
Grudpan,K.
Vichapong,J.
Motomizu,S.
Sakai,T.
author_facet Ponhong,K.
Teshima,N.
Grudpan,K.
Vichapong,J.
Motomizu,S.
Sakai,T.
author_sort Ponhong,K.
title Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
title_short Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
title_full Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
title_fullStr Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
title_full_unstemmed Successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
title_sort successive determination of urinary bilirubin and creatinine employing simultaneous injection effective mixing flow analysis
publisher Elsevier
publishDate 2015
url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84913556171&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38818
_version_ 1681421542458654720