Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand

The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms hav...

Full description

Saved in:
Bibliographic Details
Main Authors: Daunghom,K., Premrudeepreechacharn,S., Baghzouz,Y., Higuchi,K.
Format: Conference or Workshop Item
Published: 2015
Online Access:http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=78650561641&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38977
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-38977
record_format dspace
spelling th-cmuir.6653943832-389772015-06-16T08:00:57Z Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand Daunghom,K. Premrudeepreechacharn,S. Baghzouz,Y. Higuchi,K. The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms have a considerable influence to power system dynamics and must definitely be considered for analyzing power system dynamics. For this purpose, a detailed dynamic model of fully enclosed squirrel cage induction generator with gearbox (full-scale power electronics converters) of a 2.3 MW wind turbine with has been implemented using the modeling environment of the simulation software DIgSILENT PowerFactory. For investigating grid compatibility aspects of this wind generator concept, a model of a 96.6 MW wind farm, with typical layout, based on 42 wind turbines of the 2.3 MW-class has been analyzed. This paper is focusing on transient stability and fault ride through capability when the grid voltage has dropped to a very low value. ©2010 IEEE. 2015-06-16T08:00:57Z 2015-06-16T08:00:57Z 2010-12-30 Conference Paper 2-s2.0-78650561641 10.1109/ICHQP.2010.5625459 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=78650561641&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/38977
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms have a considerable influence to power system dynamics and must definitely be considered for analyzing power system dynamics. For this purpose, a detailed dynamic model of fully enclosed squirrel cage induction generator with gearbox (full-scale power electronics converters) of a 2.3 MW wind turbine with has been implemented using the modeling environment of the simulation software DIgSILENT PowerFactory. For investigating grid compatibility aspects of this wind generator concept, a model of a 96.6 MW wind farm, with typical layout, based on 42 wind turbines of the 2.3 MW-class has been analyzed. This paper is focusing on transient stability and fault ride through capability when the grid voltage has dropped to a very low value. ©2010 IEEE.
format Conference or Workshop Item
author Daunghom,K.
Premrudeepreechacharn,S.
Baghzouz,Y.
Higuchi,K.
spellingShingle Daunghom,K.
Premrudeepreechacharn,S.
Baghzouz,Y.
Higuchi,K.
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
author_facet Daunghom,K.
Premrudeepreechacharn,S.
Baghzouz,Y.
Higuchi,K.
author_sort Daunghom,K.
title Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
title_short Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
title_full Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
title_fullStr Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
title_full_unstemmed Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
title_sort fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in thailand
publishDate 2015
url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=78650561641&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/38977
_version_ 1681421571238920192