Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator

We analyze the errors of a newly proposed measurement method on optoelectronic frequency response of photodiodes, which uses a high-extinction ratio Mach-Zehnder modulator to generate a two-tone stimulus lightwave. Five major error factors are identified and analyzed quantitatively. The result shows...

Full description

Saved in:
Bibliographic Details
Main Authors: Inagaki,K., Mankong,U., Kawanishi,T.
Format: Conference or Workshop Item
Published: 2015
Online Access:http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84875979093&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/39015
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-39015
record_format dspace
spelling th-cmuir.6653943832-390152015-06-16T08:01:10Z Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator Inagaki,K. Mankong,U. Kawanishi,T. We analyze the errors of a newly proposed measurement method on optoelectronic frequency response of photodiodes, which uses a high-extinction ratio Mach-Zehnder modulator to generate a two-tone stimulus lightwave. Five major error factors are identified and analyzed quantitatively. The result shows that the evaluated combined uncertainty is expected to be less than 0.5 dB. © 2012 IEEE. 2015-06-16T08:01:10Z 2015-06-16T08:01:10Z 2012-12-01 Conference Paper 2-s2.0-84875979093 10.1109/ICOCN.2012.6486225 http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84875979093&origin=inward http://cmuir.cmu.ac.th/handle/6653943832/39015
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description We analyze the errors of a newly proposed measurement method on optoelectronic frequency response of photodiodes, which uses a high-extinction ratio Mach-Zehnder modulator to generate a two-tone stimulus lightwave. Five major error factors are identified and analyzed quantitatively. The result shows that the evaluated combined uncertainty is expected to be less than 0.5 dB. © 2012 IEEE.
format Conference or Workshop Item
author Inagaki,K.
Mankong,U.
Kawanishi,T.
spellingShingle Inagaki,K.
Mankong,U.
Kawanishi,T.
Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
author_facet Inagaki,K.
Mankong,U.
Kawanishi,T.
author_sort Inagaki,K.
title Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
title_short Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
title_full Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
title_fullStr Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
title_full_unstemmed Error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio Mach-Zehnder modulator
title_sort error analysis of optoelectronic frequency response measurement of photodiodes using high-extinction ratio mach-zehnder modulator
publishDate 2015
url http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84875979093&origin=inward
http://cmuir.cmu.ac.th/handle/6653943832/39015
_version_ 1681421578031595520