Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment

© 2017, Chiang Mai University. All rights reserved. Flow injection amperometric system has been developed for determination of phosphorus. It is based on in-line formation of 12-molybdophosphate complex, which is further electrochemically reduced on a glassy carbon working electrode at a constant ap...

Full description

Saved in:
Bibliographic Details
Main Authors: Insain P., Jakmunee J.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023774150&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40304
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40304
record_format dspace
spelling th-cmuir.6653943832-403042017-09-28T04:08:48Z Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment Insain P. Jakmunee J. © 2017, Chiang Mai University. All rights reserved. Flow injection amperometric system has been developed for determination of phosphorus. It is based on in-line formation of 12-molybdophosphate complex, which is further electrochemically reduced on a glassy carbon working electrode at a constant applied potential of 0.20 V vs. Ag/AgCl. An electrical current is directly proportional to phosphate concentration. Calibration graphs plotting between peak height and phosphate concentration were obtained in range of 0.1-1.0 and 1.0-10.0 mg L -1 P-PO 4 , with a detection limit of 0.03 mg L -1 P-PO 4 . The precision of 2.1, 2.6, 1.5, 1.2 and 1.0% (n=11, 0.1, 0.5, 1.0, 5.0 and 10.0 mg L -1 P-PO 4 , respectively) and sample throughput of 90 h -1 were achieved. The method has lower interferences (i.e., from silicate, colored and colloidal substances, and the Schlieren’s effect) than the commonly used spectrophotometric method. Although it may be interfered by cations, e.g., Fe 3+ and Al 3+ , these ions could be eliminated by using Chelex 100 resin column. The proposed system was successfully applied to determine phosphorus that sequentially leached from sediments. An off-line leaching column was proposed for fractionation of phosphorus according to Hieltjes-Lijklema scheme (HLS), employing 1.0 M NH 4 Cl, 0.1 M NaOH, and 0.5 M HCl as extractants, respectively. The results obtained from extraction by using the proposed column method and the batch shaking method were in good agreement (no significant difference at 95% confident level). 2017-09-28T04:08:48Z 2017-09-28T04:08:48Z 3 Journal 01252526 2-s2.0-85023774150 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023774150&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40304
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2017, Chiang Mai University. All rights reserved. Flow injection amperometric system has been developed for determination of phosphorus. It is based on in-line formation of 12-molybdophosphate complex, which is further electrochemically reduced on a glassy carbon working electrode at a constant applied potential of 0.20 V vs. Ag/AgCl. An electrical current is directly proportional to phosphate concentration. Calibration graphs plotting between peak height and phosphate concentration were obtained in range of 0.1-1.0 and 1.0-10.0 mg L -1 P-PO 4 , with a detection limit of 0.03 mg L -1 P-PO 4 . The precision of 2.1, 2.6, 1.5, 1.2 and 1.0% (n=11, 0.1, 0.5, 1.0, 5.0 and 10.0 mg L -1 P-PO 4 , respectively) and sample throughput of 90 h -1 were achieved. The method has lower interferences (i.e., from silicate, colored and colloidal substances, and the Schlieren’s effect) than the commonly used spectrophotometric method. Although it may be interfered by cations, e.g., Fe 3+ and Al 3+ , these ions could be eliminated by using Chelex 100 resin column. The proposed system was successfully applied to determine phosphorus that sequentially leached from sediments. An off-line leaching column was proposed for fractionation of phosphorus according to Hieltjes-Lijklema scheme (HLS), employing 1.0 M NH 4 Cl, 0.1 M NaOH, and 0.5 M HCl as extractants, respectively. The results obtained from extraction by using the proposed column method and the batch shaking method were in good agreement (no significant difference at 95% confident level).
format Journal
author Insain P.
Jakmunee J.
spellingShingle Insain P.
Jakmunee J.
Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
author_facet Insain P.
Jakmunee J.
author_sort Insain P.
title Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
title_short Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
title_full Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
title_fullStr Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
title_full_unstemmed Flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
title_sort flow injection amperometric detection and off-line sequential extraction column for fractionation of phosphorus in sediment
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023774150&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40304
_version_ 1681421785133744128