Cyclic Performance of Precast Concrete Columns Using Steel Box Connection

© 2017, Iran University of Science and Technology. This paper presents an evaluation on lateral cyclic behaviors of precast concrete columns using a steel box connection through experimental investigation. The test consisted of one monolithic reinforced concrete column as a reference and five precas...

Full description

Saved in:
Bibliographic Details
Main Authors: Hansapinyo C., Buachart C., Wongmatar P.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85020103815&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40390
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40390
record_format dspace
spelling th-cmuir.6653943832-403902017-09-28T04:09:15Z Cyclic Performance of Precast Concrete Columns Using Steel Box Connection Hansapinyo C. Buachart C. Wongmatar P. © 2017, Iran University of Science and Technology. This paper presents an evaluation on lateral cyclic behaviors of precast concrete columns using a steel box connection through experimental investigation. The test consisted of one monolithic reinforced concrete column as a reference and five precast concrete columns. All specimens had identical dimensions of 0.25 × 0.25 m 2 cross-sectional area and 1.7 m height with a longitudinal reinforcement ratio of 0.0152. Materials used for all specimens were also from the same batch. The study was aimed at understanding the design concept of the steel connecting box and detailing of column reinforcement for avoiding the brittle failure of precast concrete frame buildings. The experimental results show that without premature failure in welding or nut slipping, depending largely on the reinforcement details, the precast system with a steel box connection can be effectively used. Flexural failure mode with a ductile mechanism can be achieved to resemble the monolithic one. With a higher relative stiffness and capacities of the designed connecting box, the precast columns show a higher capacity as the failure section was shifted to an upper level. Hence, it can be said that the proper details of precast concrete columns contain acceptable seismic performances, e.g. ultimate capacity, stiffness, energy dissipation, and capacity degradation under repeated loading. 2017-09-28T04:09:15Z 2017-09-28T04:09:15Z 4 Journal 17350522 2-s2.0-85020103815 10.1007/s40999-017-0182-y https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85020103815&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40390
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2017, Iran University of Science and Technology. This paper presents an evaluation on lateral cyclic behaviors of precast concrete columns using a steel box connection through experimental investigation. The test consisted of one monolithic reinforced concrete column as a reference and five precast concrete columns. All specimens had identical dimensions of 0.25 × 0.25 m 2 cross-sectional area and 1.7 m height with a longitudinal reinforcement ratio of 0.0152. Materials used for all specimens were also from the same batch. The study was aimed at understanding the design concept of the steel connecting box and detailing of column reinforcement for avoiding the brittle failure of precast concrete frame buildings. The experimental results show that without premature failure in welding or nut slipping, depending largely on the reinforcement details, the precast system with a steel box connection can be effectively used. Flexural failure mode with a ductile mechanism can be achieved to resemble the monolithic one. With a higher relative stiffness and capacities of the designed connecting box, the precast columns show a higher capacity as the failure section was shifted to an upper level. Hence, it can be said that the proper details of precast concrete columns contain acceptable seismic performances, e.g. ultimate capacity, stiffness, energy dissipation, and capacity degradation under repeated loading.
format Journal
author Hansapinyo C.
Buachart C.
Wongmatar P.
spellingShingle Hansapinyo C.
Buachart C.
Wongmatar P.
Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
author_facet Hansapinyo C.
Buachart C.
Wongmatar P.
author_sort Hansapinyo C.
title Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
title_short Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
title_full Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
title_fullStr Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
title_full_unstemmed Cyclic Performance of Precast Concrete Columns Using Steel Box Connection
title_sort cyclic performance of precast concrete columns using steel box connection
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85020103815&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40390
_version_ 1681421800980873216