Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator

Background: Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO techniq...

Full description

Saved in:
Bibliographic Details
Main Authors: Lee H.-J., Oh C.-W., Oh J.-K., Apivatthakakul T., Kim J.-W., Yoon J.-P., Lee D.-J., Jung J.-W.
Format: Article
Language:English
Published: 2014
Online Access:http://www.scopus.com/inward/record.url?eid=2-s2.0-84877876179&partnerID=40&md5=c588d4119ce77f5da00aac2119cfb498
http://www.ncbi.nlm.nih.gov/pubmed/23463256
http://cmuir.cmu.ac.th/handle/6653943832/4052
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
Language: English
id th-cmuir.6653943832-4052
record_format dspace
spelling th-cmuir.6653943832-40522014-08-30T02:35:37Z Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator Lee H.-J. Oh C.-W. Oh J.-K. Apivatthakakul T. Kim J.-W. Yoon J.-P. Lee D.-J. Jung J.-W. Background: Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Methods: Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. Results: There was no case of mal-union >10, and mean angulation was 1.3 (range 0 -9) in the coronal plane and 1.2 (range 0 -8) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Conclusions: Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates. Level of Evidence: IV © 2013 Springer-Verlag Berlin Heidelberg. 2014-08-30T02:35:37Z 2014-08-30T02:35:37Z 2013 Article 09368051 10.1007/s00402-013-1708-7 23463256 AOTSE http://www.scopus.com/inward/record.url?eid=2-s2.0-84877876179&partnerID=40&md5=c588d4119ce77f5da00aac2119cfb498 http://www.ncbi.nlm.nih.gov/pubmed/23463256 http://cmuir.cmu.ac.th/handle/6653943832/4052 English
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
language English
description Background: Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Methods: Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. Results: There was no case of mal-union >10, and mean angulation was 1.3 (range 0 -9) in the coronal plane and 1.2 (range 0 -8) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Conclusions: Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates. Level of Evidence: IV © 2013 Springer-Verlag Berlin Heidelberg.
format Article
author Lee H.-J.
Oh C.-W.
Oh J.-K.
Apivatthakakul T.
Kim J.-W.
Yoon J.-P.
Lee D.-J.
Jung J.-W.
spellingShingle Lee H.-J.
Oh C.-W.
Oh J.-K.
Apivatthakakul T.
Kim J.-W.
Yoon J.-P.
Lee D.-J.
Jung J.-W.
Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
author_facet Lee H.-J.
Oh C.-W.
Oh J.-K.
Apivatthakakul T.
Kim J.-W.
Yoon J.-P.
Lee D.-J.
Jung J.-W.
author_sort Lee H.-J.
title Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
title_short Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
title_full Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
title_fullStr Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
title_full_unstemmed Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
title_sort minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator
publishDate 2014
url http://www.scopus.com/inward/record.url?eid=2-s2.0-84877876179&partnerID=40&md5=c588d4119ce77f5da00aac2119cfb498
http://www.ncbi.nlm.nih.gov/pubmed/23463256
http://cmuir.cmu.ac.th/handle/6653943832/4052
_version_ 1681420164599382016