Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?

© Europa Digital & Publishing 2017. All rights reserved. Aims: In the drug-eluting stent (DES) era, patients with acute coronary syndrome (ACS) had a higher risk of early stent thrombosis compared with stable patients. The present study aimed to evaluate whether the same is true for the biores...

Full description

Saved in:
Bibliographic Details
Main Authors: Sotomi Y., Miyazaki Y., Collet C., Asano T., Suwannasom P., Tijssen J., De Winter R., Waksman R., Lipinski M., Onuma Y., Serruys P.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016092605&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40710
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40710
record_format dspace
spelling th-cmuir.6653943832-407102017-09-28T04:11:01Z Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold? Sotomi Y. Miyazaki Y. Collet C. Asano T. Suwannasom P. Tijssen J. De Winter R. Waksman R. Lipinski M. Onuma Y. Serruys P. © Europa Digital & Publishing 2017. All rights reserved. Aims: In the drug-eluting stent (DES) era, patients with acute coronary syndrome (ACS) had a higher risk of early stent thrombosis compared with stable patients. The present study aimed to evaluate whether the same is true for the bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA). Methods and results: We assessed the relationship between the incidence of definite/probable scaffold thrombosis (ScT) (overall ScT and early ScT) and ACS percentage with the latest publications, including the most recent large randomised controlled trials. Out of a total study population of 13,708 devices in 45 trials, overall ScT was observed in 185 devices (1.35%) at a weighted mean follow-up period of 9.4 months, while early ScT was reported in 125 devices (0.97%) out of 12,896 devices in 44 trials. Meta-regression analysis demonstrated no significant correlation between overall/early ScT and the percentage of patients with ACS (overall ScT: R2=0.030, p=0.255; early ScT: R2=0.067, p=0.090). Conclusions: ACS appeared to have little impact on the incidence of ScT after the implantation of BVS. Further clinical study is warranted to investigate the predictors of ScT using multivariate analysis with sufficient statistical power. 2017-09-28T04:11:01Z 2017-09-28T04:11:01Z 16 Journal 1774024X 2-s2.0-85016092605 10.4244/EIJ-D-16-00472 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016092605&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40710
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © Europa Digital & Publishing 2017. All rights reserved. Aims: In the drug-eluting stent (DES) era, patients with acute coronary syndrome (ACS) had a higher risk of early stent thrombosis compared with stable patients. The present study aimed to evaluate whether the same is true for the bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA). Methods and results: We assessed the relationship between the incidence of definite/probable scaffold thrombosis (ScT) (overall ScT and early ScT) and ACS percentage with the latest publications, including the most recent large randomised controlled trials. Out of a total study population of 13,708 devices in 45 trials, overall ScT was observed in 185 devices (1.35%) at a weighted mean follow-up period of 9.4 months, while early ScT was reported in 125 devices (0.97%) out of 12,896 devices in 44 trials. Meta-regression analysis demonstrated no significant correlation between overall/early ScT and the percentage of patients with ACS (overall ScT: R2=0.030, p=0.255; early ScT: R2=0.067, p=0.090). Conclusions: ACS appeared to have little impact on the incidence of ScT after the implantation of BVS. Further clinical study is warranted to investigate the predictors of ScT using multivariate analysis with sufficient statistical power.
format Journal
author Sotomi Y.
Miyazaki Y.
Collet C.
Asano T.
Suwannasom P.
Tijssen J.
De Winter R.
Waksman R.
Lipinski M.
Onuma Y.
Serruys P.
spellingShingle Sotomi Y.
Miyazaki Y.
Collet C.
Asano T.
Suwannasom P.
Tijssen J.
De Winter R.
Waksman R.
Lipinski M.
Onuma Y.
Serruys P.
Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
author_facet Sotomi Y.
Miyazaki Y.
Collet C.
Asano T.
Suwannasom P.
Tijssen J.
De Winter R.
Waksman R.
Lipinski M.
Onuma Y.
Serruys P.
author_sort Sotomi Y.
title Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
title_short Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
title_full Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
title_fullStr Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
title_full_unstemmed Does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an Absorb bioresorbable vascular scaffold?
title_sort does acute coronary syndrome impact on the incidence of thrombosis after the implantation of an absorb bioresorbable vascular scaffold?
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016092605&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40710
_version_ 1681421867626266624