Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model

Purpose: To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. Material and methods: The Isobio software was developed using MATLA...

Full description

Saved in:
Bibliographic Details
Main Authors: Jaikuna T., Khadsiri P., Chawapun N., Saekho S., Tharavichitkul E.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016191946&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40711
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40711
record_format dspace
spelling th-cmuir.6653943832-407112017-09-28T04:11:02Z Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model Jaikuna T. Khadsiri P. Chawapun N. Saekho S. Tharavichitkul E. Purpose: To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. Material and methods: The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD2) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD2 verification with pair t-test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Results: Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D90%, 0.56% in the bladder, 1.74% in the rectum when determined by D2cc, and less than 1% in Pinnacle. The difference in the EQD2 between the software calculation and the manual calculation was not significantly different with 0.00% at p-values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. Conclusions: The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT. 2017-09-28T04:11:01Z 2017-09-28T04:11:01Z 1 Journal 1689832X 2-s2.0-85016191946 10.5114/jcb.2017.66082 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016191946&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40711
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description Purpose: To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. Material and methods: The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD2) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD2 verification with pair t-test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Results: Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D90%, 0.56% in the bladder, 1.74% in the rectum when determined by D2cc, and less than 1% in Pinnacle. The difference in the EQD2 between the software calculation and the manual calculation was not significantly different with 0.00% at p-values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. Conclusions: The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.
format Journal
author Jaikuna T.
Khadsiri P.
Chawapun N.
Saekho S.
Tharavichitkul E.
spellingShingle Jaikuna T.
Khadsiri P.
Chawapun N.
Saekho S.
Tharavichitkul E.
Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
author_facet Jaikuna T.
Khadsiri P.
Chawapun N.
Saekho S.
Tharavichitkul E.
author_sort Jaikuna T.
title Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
title_short Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
title_full Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
title_fullStr Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
title_full_unstemmed Isobio software: Biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
title_sort isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016191946&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40711
_version_ 1681421867811864576