Modified single-carrier-based modulation technique for grid-connected three-level NPC converters
© 2016 IEEE. This paper presents a modified carrier-based modulation technique for the grid-connected three-level neutral-point-clamped (NPC) converter system. The proposed carrier-based modulation technique uses the single triangular carrier signal in generating the gate signals for three-level NPC...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015407805&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40739 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-40739 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-407392017-09-28T04:11:13Z Modified single-carrier-based modulation technique for grid-connected three-level NPC converters Srirattanawichaikul W. Premrudeepreechacharn S. © 2016 IEEE. This paper presents a modified carrier-based modulation technique for the grid-connected three-level neutral-point-clamped (NPC) converter system. The proposed carrier-based modulation technique uses the single triangular carrier signal in generating the gate signals for three-level NPC converter. The control method of the grid-connected system is applied for the voltage oriented control scheme, which provides independent control active and reactive power flow into the utility grid and maintain the dc-link voltage constant. The feasibility of the developed proposed modulation technique for the grid-connected three-level NPC converter system is confirmed with experiment results, which is validated the performance and effectiveness of the presented method. 2017-09-28T04:11:13Z 2017-09-28T04:11:13Z Conference Proceeding 21593442 2-s2.0-85015407805 10.1109/TENCON.2016.7848567 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015407805&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40739 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
© 2016 IEEE. This paper presents a modified carrier-based modulation technique for the grid-connected three-level neutral-point-clamped (NPC) converter system. The proposed carrier-based modulation technique uses the single triangular carrier signal in generating the gate signals for three-level NPC converter. The control method of the grid-connected system is applied for the voltage oriented control scheme, which provides independent control active and reactive power flow into the utility grid and maintain the dc-link voltage constant. The feasibility of the developed proposed modulation technique for the grid-connected three-level NPC converter system is confirmed with experiment results, which is validated the performance and effectiveness of the presented method. |
format |
Conference Proceeding |
author |
Srirattanawichaikul W. Premrudeepreechacharn S. |
spellingShingle |
Srirattanawichaikul W. Premrudeepreechacharn S. Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
author_facet |
Srirattanawichaikul W. Premrudeepreechacharn S. |
author_sort |
Srirattanawichaikul W. |
title |
Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
title_short |
Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
title_full |
Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
title_fullStr |
Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
title_full_unstemmed |
Modified single-carrier-based modulation technique for grid-connected three-level NPC converters |
title_sort |
modified single-carrier-based modulation technique for grid-connected three-level npc converters |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015407805&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40739 |
_version_ |
1681421873051598848 |