Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging

© Europa Digital & Publishing 2017. All rights reserved. The advent of intracoronary stents has greatly increased the safety and applicability of percutaneous coronary interventions. One of the drawbacks of drug-eluting stents (DES) is the increased risk of late and very late stent thrombosis...

Full description

Saved in:
Bibliographic Details
Main Authors: Sotomi Y., Suwannasom P., Serruys P., Onuma Y.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016011234&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40803
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-40803
record_format dspace
spelling th-cmuir.6653943832-408032017-09-28T04:11:30Z Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging Sotomi Y. Suwannasom P. Serruys P. Onuma Y. © Europa Digital & Publishing 2017. All rights reserved. The advent of intracoronary stents has greatly increased the safety and applicability of percutaneous coronary interventions. One of the drawbacks of drug-eluting stents (DES) is the increased risk of late and very late stent thrombosis (ST). It was anticipated that the risks of ST after DES implantation would be solved with the advent of fully biodegradable scaffolds, which offer the possibility of transient scaffolding of the vessel to prevent acute vessel closure and recoil while also transiently eluting an antiproliferative drug to counteract constrictive remodelling and excessive neointimal hyperplasia. In spite of the enthusiasm for the concept of bioresorbable scaffolds, current clinical data on the Absorb bioresorbable vascular scaffold (BVS) have generated concerns about scaffold thrombosis (ScT) in both the early and late phases. However, the causes of ScT in both the early and late phases have yet to be fully elucidated. This article seeks to provide insights into the possible mechanical causes of ScT in the early and late phases with data stemming from intracoronary imaging (intravascular ultrasound and optical coherence tomography) of the currently published ScT cases following the implantation of BVS and reviews the practical recommendations for implantation of the BVS made by a group of experts. 2017-09-28T04:11:30Z 2017-09-28T04:11:30Z 14 Journal 1774024X 2-s2.0-85016011234 10.4244/EIJ-D-16-00471 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016011234&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/40803
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © Europa Digital & Publishing 2017. All rights reserved. The advent of intracoronary stents has greatly increased the safety and applicability of percutaneous coronary interventions. One of the drawbacks of drug-eluting stents (DES) is the increased risk of late and very late stent thrombosis (ST). It was anticipated that the risks of ST after DES implantation would be solved with the advent of fully biodegradable scaffolds, which offer the possibility of transient scaffolding of the vessel to prevent acute vessel closure and recoil while also transiently eluting an antiproliferative drug to counteract constrictive remodelling and excessive neointimal hyperplasia. In spite of the enthusiasm for the concept of bioresorbable scaffolds, current clinical data on the Absorb bioresorbable vascular scaffold (BVS) have generated concerns about scaffold thrombosis (ScT) in both the early and late phases. However, the causes of ScT in both the early and late phases have yet to be fully elucidated. This article seeks to provide insights into the possible mechanical causes of ScT in the early and late phases with data stemming from intracoronary imaging (intravascular ultrasound and optical coherence tomography) of the currently published ScT cases following the implantation of BVS and reviews the practical recommendations for implantation of the BVS made by a group of experts.
format Journal
author Sotomi Y.
Suwannasom P.
Serruys P.
Onuma Y.
spellingShingle Sotomi Y.
Suwannasom P.
Serruys P.
Onuma Y.
Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
author_facet Sotomi Y.
Suwannasom P.
Serruys P.
Onuma Y.
author_sort Sotomi Y.
title Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
title_short Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
title_full Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
title_fullStr Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
title_full_unstemmed Possible mechanical causes of scaffold thrombosis: Insights from case reports with intracoronary imaging
title_sort possible mechanical causes of scaffold thrombosis: insights from case reports with intracoronary imaging
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016011234&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/40803
_version_ 1681421884905750528