Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements

© 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to...

Full description

Saved in:
Bibliographic Details
Main Authors: Thaithet S., Hartwell S., Lapanantnoppakhun S.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/41047
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-41047
record_format dspace
spelling th-cmuir.6653943832-410472017-09-28T04:15:15Z Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements Thaithet S. Hartwell S. Lapanantnoppakhun S. © 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC. 2017-09-28T04:15:15Z 2017-09-28T04:15:15Z 2017-01-01 Journal 09106340 2-s2.0-85015175225 10.2116/analsci.33.313 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/41047
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2017, The Japan Society for Analytical Chemistry. A low-pressure separation procedure of α-tocopherol and γ-oryzanol was developed based on a sequential injection chromatography (SIC) system coupled with an ultra-short (5 mm) C-18 monolithic column, as a lower cost and more compact alternative to the HPLC system. A green sample preparation, dilution with a small amount of hexane followed by liquid-liquid extraction with 80% ethanol, was proposed. Very good separation resolution (R s = 3.26), a satisfactory separation time (10 min) and a total run time including column equilibration (16 min) were achieved. The linear working range was found to be 0.4 - 40 μg with R 2 being more than 0.99. The detection limits of both analytes were 0.28 μg with the repeatability within 5% RSD (n = 7). Quantitative analyses of the two analytes in vegetable oil and nutrition supplement samples, using the proposed SIC method, agree well with the results from HPLC.
format Journal
author Thaithet S.
Hartwell S.
Lapanantnoppakhun S.
spellingShingle Thaithet S.
Hartwell S.
Lapanantnoppakhun S.
Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
author_facet Thaithet S.
Hartwell S.
Lapanantnoppakhun S.
author_sort Thaithet S.
title Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_short Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_full Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_fullStr Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_full_unstemmed Sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
title_sort sequential injection chromatography with an ultra-short monolithic column for the low-pressure separation ofα-tocopherol and γ-oryzanol in vegetable oils and nutrition supplements
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85015175225&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/41047
_version_ 1681421929859252224