Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II
© 2016, The Korean Physical Society. The non-linear effects caused by the intrinsic field’s transverse roll-off in an elliptically polarizing undulator with a 72-mm period and a maximum peak field of 0.72 T (EPU72) on the dynamics aperture of the Pohang Light Source II (PLS-II) were investigated. A...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Journal |
Published: |
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84989288278&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/41556 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-41556 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-415562017-09-28T04:21:59Z Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II Shin S. Kim D. Huang J. Chunjarean S. © 2016, The Korean Physical Society. The non-linear effects caused by the intrinsic field’s transverse roll-off in an elliptically polarizing undulator with a 72-mm period and a maximum peak field of 0.72 T (EPU72) on the dynamics aperture of the Pohang Light Source II (PLS-II) were investigated. A kick-map and a frequency map analysis both demonstrated that EPU72 will not reduce the lifetime or cause injection problems in PLS-II. 2017-09-28T04:21:59Z 2017-09-28T04:21:59Z 2016-09-01 Journal 03744884 2-s2.0-84989288278 10.3938/jkps.69.909 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84989288278&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/41556 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
© 2016, The Korean Physical Society. The non-linear effects caused by the intrinsic field’s transverse roll-off in an elliptically polarizing undulator with a 72-mm period and a maximum peak field of 0.72 T (EPU72) on the dynamics aperture of the Pohang Light Source II (PLS-II) were investigated. A kick-map and a frequency map analysis both demonstrated that EPU72 will not reduce the lifetime or cause injection problems in PLS-II. |
format |
Journal |
author |
Shin S. Kim D. Huang J. Chunjarean S. |
spellingShingle |
Shin S. Kim D. Huang J. Chunjarean S. Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
author_facet |
Shin S. Kim D. Huang J. Chunjarean S. |
author_sort |
Shin S. |
title |
Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
title_short |
Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
title_full |
Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
title_fullStr |
Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
title_full_unstemmed |
Effects of an elliptically polarizing undulator on the beam dynamics in PLS-II |
title_sort |
effects of an elliptically polarizing undulator on the beam dynamics in pls-ii |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84989288278&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/41556 |
_version_ |
1681422023735115776 |