Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample

© 2016, Chiang Mai University. All rights reserved. A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell...

Full description

Saved in:
Bibliographic Details
Main Authors: Ruangchaiwat A., Rannurags N., Phanichphant S., Liawruangrath B., Liawruangrath S.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988956639&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/41737
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-41737
record_format dspace
spelling th-cmuir.6653943832-417372017-09-28T04:23:06Z Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample Ruangchaiwat A. Rannurags N. Phanichphant S. Liawruangrath B. Liawruangrath S. © 2016, Chiang Mai University. All rights reserved. A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell device constructed in this laboratory afterwards a double-cell device is modified from the prototype device for measuring gaseous/vapour contaminants in air. The PZT detectors were tested for detection of SO 2 on the basis of the best known SO 2 detection using triethanolamine as coating material. It was found that the dual-cell device was more sensitive to SO 2 (48 Hz ppm) than the single-cell one (6 Hz/ppm). Optimal conditions for the PZT detector were also investigated. The AT-cut quartz crystals with circular shape having thin film gold electrodes on both sides were employed. It was shown that the 10 MHz crytal coated with triethanolamine was more sentitive than the 6 MHz quartz crystal and hence the 10 MHz quartz crystal was selected as optimum. Selectivity of the PZT detector can be achieved by changing the coating materials. Under suitable conditions, choice of appropriate coating materials could be achieved for a number gaseous/vapour samples. The proposed PZT sensors using selective coatings were successfully applied for detection of SO 2 and methanol with satisfactory results. 2017-09-28T04:23:05Z 2017-09-28T04:23:05Z 2016-07-01 Journal 01252526 2-s2.0-84988956639 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988956639&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/41737
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2016, Chiang Mai University. All rights reserved. A very simple laboratory made prototype piezoelectric transducer (PZT) or sensor is described using inexpensive materials and equipment easily available in Chiang Mai and in the laboratory. Initially, experiments are carried out using a single cell device constructed in this laboratory afterwards a double-cell device is modified from the prototype device for measuring gaseous/vapour contaminants in air. The PZT detectors were tested for detection of SO 2 on the basis of the best known SO 2 detection using triethanolamine as coating material. It was found that the dual-cell device was more sensitive to SO 2 (48 Hz ppm) than the single-cell one (6 Hz/ppm). Optimal conditions for the PZT detector were also investigated. The AT-cut quartz crystals with circular shape having thin film gold electrodes on both sides were employed. It was shown that the 10 MHz crytal coated with triethanolamine was more sentitive than the 6 MHz quartz crystal and hence the 10 MHz quartz crystal was selected as optimum. Selectivity of the PZT detector can be achieved by changing the coating materials. Under suitable conditions, choice of appropriate coating materials could be achieved for a number gaseous/vapour samples. The proposed PZT sensors using selective coatings were successfully applied for detection of SO 2 and methanol with satisfactory results.
format Journal
author Ruangchaiwat A.
Rannurags N.
Phanichphant S.
Liawruangrath B.
Liawruangrath S.
spellingShingle Ruangchaiwat A.
Rannurags N.
Phanichphant S.
Liawruangrath B.
Liawruangrath S.
Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
author_facet Ruangchaiwat A.
Rannurags N.
Phanichphant S.
Liawruangrath B.
Liawruangrath S.
author_sort Ruangchaiwat A.
title Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
title_short Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
title_full Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
title_fullStr Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
title_full_unstemmed Simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
title_sort simple laboratory-made piezoelectric sensors for detection of selected gaseous and/or vapor sample
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84988956639&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/41737
_version_ 1681422057387065344