Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System

© SAGE Publications. Electrocardiography is one of the most important non-invasive diagnostic tools for diagnosing coronary heart disease. The electrocardiography information system in Maharaj Nakorn Chiang Mai Hospital required a massive manual labor effort. In this article, we propose an approach...

Full description

Saved in:
Bibliographic Details
Main Authors: Khumrin P., Chumpoo P.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84955270727&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42038
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-42038
record_format dspace
spelling th-cmuir.6653943832-420382017-09-28T04:24:52Z Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System Khumrin P. Chumpoo P. © SAGE Publications. Electrocardiography is one of the most important non-invasive diagnostic tools for diagnosing coronary heart disease. The electrocardiography information system in Maharaj Nakorn Chiang Mai Hospital required a massive manual labor effort. In this article, we propose an approach toward the integration of heterogeneous electrocardiography data and the implementation of an integrated electrocardiography information system into the existing Hospital Information System. The system integrates different electrocardiography formats into a consistent electrocardiography rendering by using Java software. The interface acts as middleware to seamlessly integrate different electrocardiography formats. Instead of using a common electrocardiography protocol, we applied a central format based on Java classes for mapping different electrocardiography formats which contains a specific parser for each electrocardiography format to acquire the same information. Our observations showed that the new system improved the effectiveness of data management, work flow, and data quality; increased the availability of information; and finally improved quality of care. 2017-09-28T04:24:52Z 2017-09-28T04:24:52Z 2016-03-01 Journal 14604582 2-s2.0-84955270727 10.1177/1460458214530981 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84955270727&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42038
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © SAGE Publications. Electrocardiography is one of the most important non-invasive diagnostic tools for diagnosing coronary heart disease. The electrocardiography information system in Maharaj Nakorn Chiang Mai Hospital required a massive manual labor effort. In this article, we propose an approach toward the integration of heterogeneous electrocardiography data and the implementation of an integrated electrocardiography information system into the existing Hospital Information System. The system integrates different electrocardiography formats into a consistent electrocardiography rendering by using Java software. The interface acts as middleware to seamlessly integrate different electrocardiography formats. Instead of using a common electrocardiography protocol, we applied a central format based on Java classes for mapping different electrocardiography formats which contains a specific parser for each electrocardiography format to acquire the same information. Our observations showed that the new system improved the effectiveness of data management, work flow, and data quality; increased the availability of information; and finally improved quality of care.
format Journal
author Khumrin P.
Chumpoo P.
spellingShingle Khumrin P.
Chumpoo P.
Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
author_facet Khumrin P.
Chumpoo P.
author_sort Khumrin P.
title Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
title_short Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
title_full Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
title_fullStr Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
title_full_unstemmed Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System
title_sort implementation of integrated heterogeneous electronic electrocardiography data into maharaj nakorn chiang mai hospital information system
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84955270727&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42038
_version_ 1681422113830862848