Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes

The objectives of this study are to experimentally investigate the effect of meandering turn numbers on thermal performance and to predict the optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes (CLPHP). The CLPHPs were made from a copper capillary tube with in...

Full description

Saved in:
Bibliographic Details
Main Authors: Kammuang-Lue N., Sakulchangsatjatai P., Sriwiset C., Terdtoon P.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85009192328&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42203
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-42203
record_format dspace
spelling th-cmuir.6653943832-422032017-09-28T04:25:45Z Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes Kammuang-Lue N. Sakulchangsatjatai P. Sriwiset C. Terdtoon P. The objectives of this study are to experimentally investigate the effect of meandering turn numbers on thermal performance and to predict the optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes (CLPHP). The CLPHPs were made from a copper capillary tube with internal diameter of 2.0 mm. The CLPHPs were bent into undulating tubes with various meandering turn numbers, such as 5, 7, 10, 16, and 30. Each set of the CLPHPs had different evaporator section lengths of 50 mm and 150 mm. Heat input was supplied to the CLPHP by allowing the flow of distilled water as the heating medium through the evaporator section. The adiabatic section temperature was constantly controlled at 50 °C. It could be concluded that the optimum meandering turn number of vertical CLPHPs with an evaporator section length of 50 mm is 10 for both R123 and water, and the optimum meandering turn numbers of vertical CLPHPs with an evaporator section length of 150 mm are 5 and 10, respectively, for R123 and water. However, the optimum meandering turn number of the horizontal CLPHP could not be found since the heat flux directly varies with the turn number. In addition, the correlation to predict the optimum meandering turn number of the vertical CLPHP was successfully established. 2017-09-28T04:25:45Z 2017-09-28T04:25:45Z 2016-01-01 Journal 03549836 2-s2.0-85009192328 10.2298/TSCI150707161K https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85009192328&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42203
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description The objectives of this study are to experimentally investigate the effect of meandering turn numbers on thermal performance and to predict the optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes (CLPHP). The CLPHPs were made from a copper capillary tube with internal diameter of 2.0 mm. The CLPHPs were bent into undulating tubes with various meandering turn numbers, such as 5, 7, 10, 16, and 30. Each set of the CLPHPs had different evaporator section lengths of 50 mm and 150 mm. Heat input was supplied to the CLPHP by allowing the flow of distilled water as the heating medium through the evaporator section. The adiabatic section temperature was constantly controlled at 50 °C. It could be concluded that the optimum meandering turn number of vertical CLPHPs with an evaporator section length of 50 mm is 10 for both R123 and water, and the optimum meandering turn numbers of vertical CLPHPs with an evaporator section length of 150 mm are 5 and 10, respectively, for R123 and water. However, the optimum meandering turn number of the horizontal CLPHP could not be found since the heat flux directly varies with the turn number. In addition, the correlation to predict the optimum meandering turn number of the vertical CLPHP was successfully established.
format Journal
author Kammuang-Lue N.
Sakulchangsatjatai P.
Sriwiset C.
Terdtoon P.
spellingShingle Kammuang-Lue N.
Sakulchangsatjatai P.
Sriwiset C.
Terdtoon P.
Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
author_facet Kammuang-Lue N.
Sakulchangsatjatai P.
Sriwiset C.
Terdtoon P.
author_sort Kammuang-Lue N.
title Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_short Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_full Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_fullStr Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_full_unstemmed Investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
title_sort investigation and predictation of optimum meandering turn number of vertical and horizontal closed-loop pulsating heat pipes
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85009192328&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42203
_version_ 1681422144732397568