Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations

© 2016 The Authors. This paper presents the comparison of back-flashover rate (BFR) by applying the CIGRE method and the IEEE-Flash software. The BFR on 230 kV single and double circuits transmission lines have been compared. Firstly, the BFR from the two iterative methods, CIGRE and the simplified...

Full description

Saved in:
Bibliographic Details
Main Author: Thanasaksiri T.
Format: Conference Proceeding
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84999836734&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42349
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-42349
record_format dspace
spelling th-cmuir.6653943832-423492017-09-28T04:26:37Z Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations Thanasaksiri T. © 2016 The Authors. This paper presents the comparison of back-flashover rate (BFR) by applying the CIGRE method and the IEEE-Flash software. The BFR on 230 kV single and double circuits transmission lines have been compared. Firstly, the BFR from the two iterative methods, CIGRE and the simplified methods, have been compared then the BFR using CIGRE method has been chosen in order to compare the results with the IEEE-Flash software. The IEEE-Flash software gives the BFR significantly higher than the CIGRE method for 230 kV double circuits but not for the single circuit. 2017-09-28T04:26:37Z 2017-09-28T04:26:37Z 2016-01-01 Conference Proceeding 2-s2.0-84999836734 10.1016/j.procs.2016.05.077 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84999836734&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42349
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2016 The Authors. This paper presents the comparison of back-flashover rate (BFR) by applying the CIGRE method and the IEEE-Flash software. The BFR on 230 kV single and double circuits transmission lines have been compared. Firstly, the BFR from the two iterative methods, CIGRE and the simplified methods, have been compared then the BFR using CIGRE method has been chosen in order to compare the results with the IEEE-Flash software. The IEEE-Flash software gives the BFR significantly higher than the CIGRE method for 230 kV double circuits but not for the single circuit.
format Conference Proceeding
author Thanasaksiri T.
spellingShingle Thanasaksiri T.
Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
author_facet Thanasaksiri T.
author_sort Thanasaksiri T.
title Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
title_short Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
title_full Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
title_fullStr Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
title_full_unstemmed Comparison of CIGRE Method and IEEE-Flash Software for Back-flashover Rate Calculations
title_sort comparison of cigre method and ieee-flash software for back-flashover rate calculations
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84999836734&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42349
_version_ 1681422172624519168