A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren

This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM 10 . The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with...

Full description

Saved in:
Bibliographic Details
Main Authors: Phornwisetsirikun W., Prapamontol T., Chantara S., Thavornyutikarn P., Rangkakulnuwat S.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42384
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-42384
record_format dspace
spelling th-cmuir.6653943832-423842017-09-28T04:26:45Z A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren Phornwisetsirikun W. Prapamontol T. Chantara S. Thavornyutikarn P. Rangkakulnuwat S. This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM 10 . The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with five healthy volunteers. All five volunteers tolerated the device well, completing the EBC collection procedure without difficulty. Collecting normal tidal breathing for 10 minutes yielded the required EBC volume. We conducted a follow-up study with 104 healthy schoolchildren from two different primary schools in Chiang Mai, Thailand. We measured exhaled H 2 O 2 concentrations in both the rainy and dry season; ambient PM 10 was significantly higher in the dry season. In the dry season, the mean exhaled H 2 O 2 concentration was significantly higher in both groups (p < 0.05). This study showed that the developed EBC collector device was cost effective, safe, rapid, and simple to use and exhaled H 2 O 2 could be used as a biomarker for elevated PM 10 exposure before clinical symptoms appeared. 2017-09-28T04:26:45Z 2017-09-28T04:26:45Z 2016-01-01 Journal 16851994 2-s2.0-84962591929 10.12982/cmujns.2016.0004 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42384
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description This study developed a portable device to collect exhaled breath condensate (EBC) and used it to collect EBC samples from schoolchildren exposed to ambient PM 10 . The developed device was validated, including investigating the effect of collecting duration and breathing patterns on EBC volume, with five healthy volunteers. All five volunteers tolerated the device well, completing the EBC collection procedure without difficulty. Collecting normal tidal breathing for 10 minutes yielded the required EBC volume. We conducted a follow-up study with 104 healthy schoolchildren from two different primary schools in Chiang Mai, Thailand. We measured exhaled H 2 O 2 concentrations in both the rainy and dry season; ambient PM 10 was significantly higher in the dry season. In the dry season, the mean exhaled H 2 O 2 concentration was significantly higher in both groups (p < 0.05). This study showed that the developed EBC collector device was cost effective, safe, rapid, and simple to use and exhaled H 2 O 2 could be used as a biomarker for elevated PM 10 exposure before clinical symptoms appeared.
format Journal
author Phornwisetsirikun W.
Prapamontol T.
Chantara S.
Thavornyutikarn P.
Rangkakulnuwat S.
spellingShingle Phornwisetsirikun W.
Prapamontol T.
Chantara S.
Thavornyutikarn P.
Rangkakulnuwat S.
A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
author_facet Phornwisetsirikun W.
Prapamontol T.
Chantara S.
Thavornyutikarn P.
Rangkakulnuwat S.
author_sort Phornwisetsirikun W.
title A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
title_short A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
title_full A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
title_fullStr A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
title_full_unstemmed A simple device for collecting exhaled breath condensate (EBC) to study inflammatory biomarkers of PM<inf>10</inf> exposure in Thai schoolchildren
title_sort simple device for collecting exhaled breath condensate (ebc) to study inflammatory biomarkers of pm<inf>10</inf> exposure in thai schoolchildren
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84962591929&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/42384
_version_ 1681422179189653504