Studies of lightning overvoltages of 115 kV CMU GIS substation
This paper presents the analysis of lightning overvoltage for the new coming 115 kV CMU (ChiangMai University) GIS (Gas Insulated Switchgear) substation applying simplified models. The GIS being considered here is connected to an overhead line through XLPE underground cables. The sensitivity analysi...
Saved in:
Main Author: | |
---|---|
Format: | Conference Proceeding |
Published: |
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866759996&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42753 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-42753 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-427532017-09-28T06:38:33Z Studies of lightning overvoltages of 115 kV CMU GIS substation Thanasaksiri T. This paper presents the analysis of lightning overvoltage for the new coming 115 kV CMU (ChiangMai University) GIS (Gas Insulated Switchgear) substation applying simplified models. The GIS being considered here is connected to an overhead line through XLPE underground cables. The sensitivity analysis of lightning overvoltage have been evaluated using ATP-EMTP. Factors including, pole footing resistance, cable length and additional surge arrester installed which gives the variation of overvoltages in GIS have also been considered. Finally, means to reduce the lightning overvoltages for the new coming 115 kV CMU GIS substation will be recommended. © 2012 IEEE. 2017-09-28T06:38:33Z 2017-09-28T06:38:33Z 2012-10-02 Conference Proceeding 2-s2.0-84866759996 10.1109/ECTICon.2012.6254221 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866759996&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42753 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
This paper presents the analysis of lightning overvoltage for the new coming 115 kV CMU (ChiangMai University) GIS (Gas Insulated Switchgear) substation applying simplified models. The GIS being considered here is connected to an overhead line through XLPE underground cables. The sensitivity analysis of lightning overvoltage have been evaluated using ATP-EMTP. Factors including, pole footing resistance, cable length and additional surge arrester installed which gives the variation of overvoltages in GIS have also been considered. Finally, means to reduce the lightning overvoltages for the new coming 115 kV CMU GIS substation will be recommended. © 2012 IEEE. |
format |
Conference Proceeding |
author |
Thanasaksiri T. |
spellingShingle |
Thanasaksiri T. Studies of lightning overvoltages of 115 kV CMU GIS substation |
author_facet |
Thanasaksiri T. |
author_sort |
Thanasaksiri T. |
title |
Studies of lightning overvoltages of 115 kV CMU GIS substation |
title_short |
Studies of lightning overvoltages of 115 kV CMU GIS substation |
title_full |
Studies of lightning overvoltages of 115 kV CMU GIS substation |
title_fullStr |
Studies of lightning overvoltages of 115 kV CMU GIS substation |
title_full_unstemmed |
Studies of lightning overvoltages of 115 kV CMU GIS substation |
title_sort |
studies of lightning overvoltages of 115 kv cmu gis substation |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84866759996&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/42753 |
_version_ |
1681422249097166848 |