Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease

Objective: To assess the effectiveness of liver length measurement in predicting hemoglobin (Hb) Bart's disease among fetuses at risk at mid-pregnancy. Study Design: Pregnant women at risk of fetal Hb Bart's disease at 18 to 22 weeks of gestation were enrolled in the study. All of them und...

Full description

Saved in:
Bibliographic Details
Main Authors: Luewan S., Tongprasert F., Piyamongkol W., Wanapirak C., Tongsong T.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79952317787&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43092
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43092
record_format dspace
spelling th-cmuir.6653943832-430922017-09-28T06:47:38Z Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease Luewan S. Tongprasert F. Piyamongkol W. Wanapirak C. Tongsong T. Objective: To assess the effectiveness of liver length measurement in predicting hemoglobin (Hb) Bart's disease among fetuses at risk at mid-pregnancy. Study Design: Pregnant women at risk of fetal Hb Bart's disease at 18 to 22 weeks of gestation were enrolled in the study. All of them underwent liver length measurement just before cordocentesis for fetal blood analysis. The final diagnosis used as a gold standard was based on fetal Hb typing using high-performance liquid chromatography. Result: A total of 334 pregnant women were recruited into the study. The prevalence of fetal Hb Bart's disease was 26.1% (87 of 334 fetuses). The sensitivity, specificity, as well as positive and negative predictive values of liver length in the prediction of affected fetuses were 71.3, 95.5, 84.9 and 90.4%, respectively. Overall, 24 fetuses (27.6%) had some degree of early hydrops fetalis. Of these, 20 had hepatomegaly as well. Conclusion: Liver length measurements at mid-pregnancy may be helpful in predicting affected fetuses among pregnancies at risk. Normal liver length measurement is associated with a very low risk of the disease. This information may help couples decide on whether to opt for either invasive diagnosis or a noninvasive approach, especially when used as an adjunct to other tests. © 2011 Nature America, Inc. All rights reserved. 2017-09-28T06:47:38Z 2017-09-28T06:47:38Z 2011-03-01 Journal 07438346 2-s2.0-79952317787 10.1038/jp.2010.84 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79952317787&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43092
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description Objective: To assess the effectiveness of liver length measurement in predicting hemoglobin (Hb) Bart's disease among fetuses at risk at mid-pregnancy. Study Design: Pregnant women at risk of fetal Hb Bart's disease at 18 to 22 weeks of gestation were enrolled in the study. All of them underwent liver length measurement just before cordocentesis for fetal blood analysis. The final diagnosis used as a gold standard was based on fetal Hb typing using high-performance liquid chromatography. Result: A total of 334 pregnant women were recruited into the study. The prevalence of fetal Hb Bart's disease was 26.1% (87 of 334 fetuses). The sensitivity, specificity, as well as positive and negative predictive values of liver length in the prediction of affected fetuses were 71.3, 95.5, 84.9 and 90.4%, respectively. Overall, 24 fetuses (27.6%) had some degree of early hydrops fetalis. Of these, 20 had hepatomegaly as well. Conclusion: Liver length measurements at mid-pregnancy may be helpful in predicting affected fetuses among pregnancies at risk. Normal liver length measurement is associated with a very low risk of the disease. This information may help couples decide on whether to opt for either invasive diagnosis or a noninvasive approach, especially when used as an adjunct to other tests. © 2011 Nature America, Inc. All rights reserved.
format Journal
author Luewan S.
Tongprasert F.
Piyamongkol W.
Wanapirak C.
Tongsong T.
spellingShingle Luewan S.
Tongprasert F.
Piyamongkol W.
Wanapirak C.
Tongsong T.
Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
author_facet Luewan S.
Tongprasert F.
Piyamongkol W.
Wanapirak C.
Tongsong T.
author_sort Luewan S.
title Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
title_short Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
title_full Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
title_fullStr Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
title_full_unstemmed Fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin Bart's disease
title_sort fetal liver length measurement at mid-pregnancy among fetuses at risk as a predictor of hemoglobin bart's disease
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=79952317787&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43092
_version_ 1681422313158868992