Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system
THE interaction between a fault arc and the power system has a big influence on evaluation of sucessful reclosing of a faulted system. In this paper, the single phase reclosing performance of the system is considered using Thailand 500 kV transmission system between Mae Moh and Tha Ta Ko substations...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954945374&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43261 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-43261 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-432612017-09-28T06:53:10Z Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system Ngamsanroaj K. Premrudeeprechacharn S. THE interaction between a fault arc and the power system has a big influence on evaluation of sucessful reclosing of a faulted system. In this paper, the single phase reclosing performance of the system is considered using Thailand 500 kV transmission system between Mae Moh and Tha Ta Ko substations as examples. The work has been investigated using simplified arc model. The study has used EMTP simulation to analyse the behavior of the system response to switching operation. The illustrative cases are also presented in order to determine approximately the maximum arc duration that may be expected. 2017-09-28T06:53:10Z 2017-09-28T06:53:10Z 2010-07-30 Conference Proceeding 2-s2.0-77954945374 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954945374&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43261 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
THE interaction between a fault arc and the power system has a big influence on evaluation of sucessful reclosing of a faulted system. In this paper, the single phase reclosing performance of the system is considered using Thailand 500 kV transmission system between Mae Moh and Tha Ta Ko substations as examples. The work has been investigated using simplified arc model. The study has used EMTP simulation to analyse the behavior of the system response to switching operation. The illustrative cases are also presented in order to determine approximately the maximum arc duration that may be expected. |
format |
Conference Proceeding |
author |
Ngamsanroaj K. Premrudeeprechacharn S. |
spellingShingle |
Ngamsanroaj K. Premrudeeprechacharn S. Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
author_facet |
Ngamsanroaj K. Premrudeeprechacharn S. |
author_sort |
Ngamsanroaj K. |
title |
Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
title_short |
Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
title_full |
Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
title_fullStr |
Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
title_full_unstemmed |
Performance study of single phase reclosing using simplified arc model on the Thailand 500 kV system |
title_sort |
performance study of single phase reclosing using simplified arc model on the thailand 500 kv system |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954945374&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43261 |
_version_ |
1681422344780775424 |