Lightning performance of covered conductors overhead distribution lines

This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failur...

Full description

Saved in:
Bibliographic Details
Main Author: Thanasaksiri T.
Format: Conference Proceeding
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43262
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43262
record_format dspace
spelling th-cmuir.6653943832-432622017-09-28T06:53:10Z Lightning performance of covered conductors overhead distribution lines Thanasaksiri T. This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failure flashover rate (SFFOR) and induced voltage flashover rate (IVFOR) of line have been determined. The number of lightning flashovers from simulation, by applying ground flash density Ng=6.5x10-5Td 2.277, are close with the data from the line outages recorder. 2017-09-28T06:53:10Z 2017-09-28T06:53:10Z 2010-07-30 Conference Proceeding 2-s2.0-77954925654 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43262
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description This paper analyzes the lightning performance of 22 kV, ChiangMai substation 4 to Doi-Suthep, overhead distribution line with covered conductors. The performance of line which related to the insulator flashover has been modeled and analyzed using EMTP. The backflashover rate (BFOR), shielding failure flashover rate (SFFOR) and induced voltage flashover rate (IVFOR) of line have been determined. The number of lightning flashovers from simulation, by applying ground flash density Ng=6.5x10-5Td 2.277, are close with the data from the line outages recorder.
format Conference Proceeding
author Thanasaksiri T.
spellingShingle Thanasaksiri T.
Lightning performance of covered conductors overhead distribution lines
author_facet Thanasaksiri T.
author_sort Thanasaksiri T.
title Lightning performance of covered conductors overhead distribution lines
title_short Lightning performance of covered conductors overhead distribution lines
title_full Lightning performance of covered conductors overhead distribution lines
title_fullStr Lightning performance of covered conductors overhead distribution lines
title_full_unstemmed Lightning performance of covered conductors overhead distribution lines
title_sort lightning performance of covered conductors overhead distribution lines
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954925654&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43262
_version_ 1681422344977907712