Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand
The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms hav...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Published: |
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954765994&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43265 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-43265 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-432652017-09-28T06:53:16Z Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand Daunghom K. Premrudeepreechacharn S. The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms have a considerable influence to power system dynamics and must definitely be considered for analyzing power system dynamics. For this purpose, a detailed dynamic model of fully enclosed squirrel cage induction generator with gearbox (full-scale power electronics converters) of a 2.3 MW wind turbine with has been implemented using the modeling environment of the simulation software DIgSILENT PowerFactory. For investigating grid compatibility aspects of this wind generator concept, a model of a 96.6 MW wind farm, with typical layout, based on 42 wind turbines of the 2.3 MW-class has been analyzed. This paper is focusing on transient stability and fault ride through capability when the grid voltage has dropped to a very low value. © 2010 IEEE. 2017-09-28T06:53:16Z 2017-09-28T06:53:16Z 2010-07-26 Conference Proceeding 2-s2.0-77954765994 10.1109/TDC.2010.5484266 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954765994&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43265 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
The increasing amount of wind power generation in Thailand power systems requires stability analysis considering interaction between wind-farms and transmission systems. Dynamics introduced by dispersed wind generators at the distribution level can usually be neglected. However, large wind farms have a considerable influence to power system dynamics and must definitely be considered for analyzing power system dynamics. For this purpose, a detailed dynamic model of fully enclosed squirrel cage induction generator with gearbox (full-scale power electronics converters) of a 2.3 MW wind turbine with has been implemented using the modeling environment of the simulation software DIgSILENT PowerFactory. For investigating grid compatibility aspects of this wind generator concept, a model of a 96.6 MW wind farm, with typical layout, based on 42 wind turbines of the 2.3 MW-class has been analyzed. This paper is focusing on transient stability and fault ride through capability when the grid voltage has dropped to a very low value. © 2010 IEEE. |
format |
Conference Proceeding |
author |
Daunghom K. Premrudeepreechacharn S. |
spellingShingle |
Daunghom K. Premrudeepreechacharn S. Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
author_facet |
Daunghom K. Premrudeepreechacharn S. |
author_sort |
Daunghom K. |
title |
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
title_short |
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
title_full |
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
title_fullStr |
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
title_full_unstemmed |
Fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in Thailand |
title_sort |
fault ride-through of fully enclosed squirrel-cage induction generators for wind farms in thailand |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954765994&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43265 |
_version_ |
1681422345532604416 |