Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry

We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection...

Full description

Saved in:
Bibliographic Details
Main Authors: Ganranoo L., Mishra S., Azad A., Shigihara A., Dasgupta P., Breitbach Z., Armstrong D., Grudpan K., Rappenglueck B.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43276
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43276
record_format dspace
spelling th-cmuir.6653943832-432762017-09-28T06:53:30Z Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry Ganranoo L. Mishra S. Azad A. Shigihara A. Dasgupta P. Breitbach Z. Armstrong D. Grudpan K. Rappenglueck B. We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection of 100 μL of 0.1 M Na 2 SO 4 on to a short (2×50 mm) reverse phase C-18 column packed with 2.2 μm particles. The salt plug passes through the C-18 column unretained while the NPs are separated by an ammonium acetate buffered methanol-water eluent, compatible with mass spectrometry (MS). The eluted NPs are measured with a long path Teflon AF-based liquid core waveguide (0.15×1420 mm) illuminated by a 403 nm light emitting diode and detected by a monolithic photodiode-operational amplifier. The waveguide is rendered chemically active by suspending it over concentrated ammonia that permeates into the lumen. The NPs ionize to the yellow anion form (λ max ∼400 nm). The separation of 4-nitrophenol, 2,4-dinitrophenol, 2-methyl-4-nitrophenol, 3-methyl-4-nitrophenol, and 2-nitrophenol (these are the dominant NPs, typically in that order, in both rain and air of Houston and Arlington, TX, confirmed by tandem MS) takes just over 5 min with respective S/N = 3 limits of detection (LODs) of 60, 12, 30, 67, and 23 pg/mL compared to MS/MS LODs of 20, 49, 11, 20, and 210 pg/mL. Illustrative air and rain data are presented. © 2010 American Chemical Society. 2017-09-28T06:53:30Z 2017-09-28T06:53:30Z 2010-07-01 Journal 00032700 2-s2.0-77954194438 10.1021/ac101015y https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43276
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description We report a novel system to analyze atmospheric nitrophenols (NPs). Rain or air sample extracts (1 mL) are preconcentrated on a narrow bore (2 mm) aliphatic anion exchanger. In the absence of strong retention of NPs exhibited by aromatic ion exchangers, retained NPs are eluted as a plug by injection of 100 μL of 0.1 M Na 2 SO 4 on to a short (2×50 mm) reverse phase C-18 column packed with 2.2 μm particles. The salt plug passes through the C-18 column unretained while the NPs are separated by an ammonium acetate buffered methanol-water eluent, compatible with mass spectrometry (MS). The eluted NPs are measured with a long path Teflon AF-based liquid core waveguide (0.15×1420 mm) illuminated by a 403 nm light emitting diode and detected by a monolithic photodiode-operational amplifier. The waveguide is rendered chemically active by suspending it over concentrated ammonia that permeates into the lumen. The NPs ionize to the yellow anion form (λ max ∼400 nm). The separation of 4-nitrophenol, 2,4-dinitrophenol, 2-methyl-4-nitrophenol, 3-methyl-4-nitrophenol, and 2-nitrophenol (these are the dominant NPs, typically in that order, in both rain and air of Houston and Arlington, TX, confirmed by tandem MS) takes just over 5 min with respective S/N = 3 limits of detection (LODs) of 60, 12, 30, 67, and 23 pg/mL compared to MS/MS LODs of 20, 49, 11, 20, and 210 pg/mL. Illustrative air and rain data are presented. © 2010 American Chemical Society.
format Journal
author Ganranoo L.
Mishra S.
Azad A.
Shigihara A.
Dasgupta P.
Breitbach Z.
Armstrong D.
Grudpan K.
Rappenglueck B.
spellingShingle Ganranoo L.
Mishra S.
Azad A.
Shigihara A.
Dasgupta P.
Breitbach Z.
Armstrong D.
Grudpan K.
Rappenglueck B.
Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
author_facet Ganranoo L.
Mishra S.
Azad A.
Shigihara A.
Dasgupta P.
Breitbach Z.
Armstrong D.
Grudpan K.
Rappenglueck B.
author_sort Ganranoo L.
title Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
title_short Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
title_full Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
title_fullStr Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
title_full_unstemmed Measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
title_sort measurement of nitrophenols in rain and air by two-dimensional liquid chromatography-chemically active liquid core waveguide spectrometry
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=77954194438&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43276
_version_ 1681422347578376192