Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement

This paper presents the performance of a wire-on-tube heat exchanger of which the wire is an oscillating heat pipe. The experiments for this heat exchanger were performed in a wind tunnel by exchanging heat between hot water flowing inside the heat exchanger tubes and air stream flowing across the e...

Full description

Saved in:
Bibliographic Details
Main Authors: Nuntaphan A., Vithayasai S., Vorayos N., Kiatsiriroat T.
Format: Journal
Published: 2017
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75149190349&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43334
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43334
record_format dspace
spelling th-cmuir.6653943832-433342017-09-28T06:54:42Z Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement Nuntaphan A. Vithayasai S. Vorayos N. Vorayos N. Kiatsiriroat T. This paper presents the performance of a wire-on-tube heat exchanger of which the wire is an oscillating heat pipe. The experiments for this heat exchanger were performed in a wind tunnel by exchanging heat between hot water flowing inside the heat exchanger tubes and air stream flowing across the external surface. R123, methanol and acetone were selected as working fluids of the oscillating heat pipe. The inlet water temperature was varied from 45 to 85 °C while the inlet air temperature was kept constant at 25 °C. The results show that the oscillating heat pipe technique for all working fluids could increase around 10% of the heat transfer rate obtained from that without the refrigerant flow in the capillary tube when the inlet water temperature is at 60 °C. Moreover, the heat transfer models for evaluating the heat exchanger effectiveness and the air-side heat transfer coefficient, are also developed in this work. These results of the models agreed very well with the experimental data. © 2009 Elsevier Ltd. All rights reserved. 2017-09-28T06:54:42Z 2017-09-28T06:54:42Z 2010-03-01 Journal 07351933 2-s2.0-75149190349 10.1016/j.icheatmasstransfer.2009.11.006 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75149190349&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43334
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description This paper presents the performance of a wire-on-tube heat exchanger of which the wire is an oscillating heat pipe. The experiments for this heat exchanger were performed in a wind tunnel by exchanging heat between hot water flowing inside the heat exchanger tubes and air stream flowing across the external surface. R123, methanol and acetone were selected as working fluids of the oscillating heat pipe. The inlet water temperature was varied from 45 to 85 °C while the inlet air temperature was kept constant at 25 °C. The results show that the oscillating heat pipe technique for all working fluids could increase around 10% of the heat transfer rate obtained from that without the refrigerant flow in the capillary tube when the inlet water temperature is at 60 °C. Moreover, the heat transfer models for evaluating the heat exchanger effectiveness and the air-side heat transfer coefficient, are also developed in this work. These results of the models agreed very well with the experimental data. © 2009 Elsevier Ltd. All rights reserved.
format Journal
author Nuntaphan A.
Vithayasai S.
Vorayos N.
Vorayos N.
Kiatsiriroat T.
spellingShingle Nuntaphan A.
Vithayasai S.
Vorayos N.
Vorayos N.
Kiatsiriroat T.
Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
author_facet Nuntaphan A.
Vithayasai S.
Vorayos N.
Vorayos N.
Kiatsiriroat T.
author_sort Nuntaphan A.
title Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
title_short Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
title_full Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
title_fullStr Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
title_full_unstemmed Use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
title_sort use of oscillating heat pipe technique as extended surface in wire-on-tube heat exchanger for heat transfer enhancement
publishDate 2017
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=75149190349&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43334
_version_ 1681422358308454400