Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)

© 2017, Veteriner Fakultesi Dergisi. All rights reserved. Ponies used in equine-assisted therapy (EAT) (hippotherapy) often carry imbalanced riders, which is a cause for concern as regards the health of the ponies. A low degree of lameness or an abnormal gait is not always detectable by a veterinari...

Full description

Saved in:
Bibliographic Details
Main Authors: Siriporn Peansukmanee, Nuanlaor Thawinchai, Prakaykul Khanproa, Prayanee Khaminluang
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030328243&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43704
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43704
record_format dspace
spelling th-cmuir.6653943832-437042018-04-25T07:29:33Z Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT) Siriporn Peansukmanee Nuanlaor Thawinchai Prakaykul Khanproa Prayanee Khaminluang Agricultural and Biological Sciences © 2017, Veteriner Fakultesi Dergisi. All rights reserved. Ponies used in equine-assisted therapy (EAT) (hippotherapy) often carry imbalanced riders, which is a cause for concern as regards the health of the ponies. A low degree of lameness or an abnormal gait is not always detectable by a veterinarian, subjectively, but this is enabled by using a motion analysis equipment. The aim of this study was to evaluate the feasibility of inertial sensor technology utilization to analyze ponies’ kinematic motion at walking gait. Ten ponies were instrumented with the inertial sensors and made to walk 20 m in two trials (departure and return) for the forelimb data set (n=10), which was then repeated in the second round for the hindlimb (n=3). The ponies were assigned three interventions: walking with no rider, walking with a rider with typical development (normal rider), and walking with a rider with physical disability (disabled rider). The movement speed, stride length, and stride duration were measured by a video camera. The limb range of motion and the angular velocity were detected by inertial sensors. The results showed that there were no significant differences in the kinematic motion of the forelimb at walking gait for all interventions and no significant differences between the left and the right forelimbs except in the case of the anterior phase of the angular velocity of the arm when walking with a disabled rider (P < 0.05). The hindlimb data set was not statistically compared due to insufficient “n” number. In conclusion, the inertial sensor technology is feasible to use on pony kinematic motion, especially when the sensor is attached to the forelimb. It seems that the ponies could modify the natural kinematic motion when walking with a load on them. 2018-01-24T03:56:19Z 2018-01-24T03:56:19Z 2017-01-01 Journal 13092251 13006045 2-s2.0-85030328243 10.9775/kvfd.2017.17833 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030328243&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43704
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Agricultural and Biological Sciences
spellingShingle Agricultural and Biological Sciences
Siriporn Peansukmanee
Nuanlaor Thawinchai
Prakaykul Khanproa
Prayanee Khaminluang
Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
description © 2017, Veteriner Fakultesi Dergisi. All rights reserved. Ponies used in equine-assisted therapy (EAT) (hippotherapy) often carry imbalanced riders, which is a cause for concern as regards the health of the ponies. A low degree of lameness or an abnormal gait is not always detectable by a veterinarian, subjectively, but this is enabled by using a motion analysis equipment. The aim of this study was to evaluate the feasibility of inertial sensor technology utilization to analyze ponies’ kinematic motion at walking gait. Ten ponies were instrumented with the inertial sensors and made to walk 20 m in two trials (departure and return) for the forelimb data set (n=10), which was then repeated in the second round for the hindlimb (n=3). The ponies were assigned three interventions: walking with no rider, walking with a rider with typical development (normal rider), and walking with a rider with physical disability (disabled rider). The movement speed, stride length, and stride duration were measured by a video camera. The limb range of motion and the angular velocity were detected by inertial sensors. The results showed that there were no significant differences in the kinematic motion of the forelimb at walking gait for all interventions and no significant differences between the left and the right forelimbs except in the case of the anterior phase of the angular velocity of the arm when walking with a disabled rider (P < 0.05). The hindlimb data set was not statistically compared due to insufficient “n” number. In conclusion, the inertial sensor technology is feasible to use on pony kinematic motion, especially when the sensor is attached to the forelimb. It seems that the ponies could modify the natural kinematic motion when walking with a load on them.
format Journal
author Siriporn Peansukmanee
Nuanlaor Thawinchai
Prakaykul Khanproa
Prayanee Khaminluang
author_facet Siriporn Peansukmanee
Nuanlaor Thawinchai
Prakaykul Khanproa
Prayanee Khaminluang
author_sort Siriporn Peansukmanee
title Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
title_short Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
title_full Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
title_fullStr Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
title_full_unstemmed Feasibility study of inertial sensor technology on ponies for equine-assisted therapy (EAT)
title_sort feasibility study of inertial sensor technology on ponies for equine-assisted therapy (eat)
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85030328243&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43704
_version_ 1681422422664806400