Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate

© 2017 Elsevier B.V. A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The...

Full description

Saved in:
Bibliographic Details
Main Authors: Wanpen Khongpet, Somkid Pencharee, Chanida Puangpila, Supaporn Kradtap Hartwell, Somchai Lapanantnoppakhun, Jaroon Jakmunee
Format: Journal
Published: 2018
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85029746236&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43855
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43855
record_format dspace
spelling th-cmuir.6653943832-438552018-01-24T04:14:19Z Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate Wanpen Khongpet Somkid Pencharee Chanida Puangpila Supaporn Kradtap Hartwell Somchai Lapanantnoppakhun Jaroon Jakmunee © 2017 Elsevier B.V. A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1–6 mg P L −1 was obtained. The detection limit was 0.1 mg L −1 . The system is compact (5.0 mm thick, 80 mm wide × 140 mm long), durable, portable, cost-effective, and consumes little amount of chemicals (83 μL each of molybdate and ascorbic acid, 133 μL of the sample solution and 1.7 mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2–107.3. The results obtained agreed well with those of the batch spectrophotometric method. 2018-01-24T04:14:19Z 2018-01-24T04:14:19Z 2018-01-15 Journal 00399140 2-s2.0-85029746236 10.1016/j.talanta.2017.09.018 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85029746236&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43855
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2017 Elsevier B.V. A microfluidic hydrodynamic sequential injection (μHSI) spectrophotometric system was designed and fabricated. The system was built by laser engraving a manifold pattern on an acrylic block and sealing with another flat acrylic plate to form a microfluidic channel platform. The platform was incorporated with small solenoid valves to obtain a portable setup for programmable control of the liquid flow into the channel according to the HSI principle. The system was demonstrated for the determination of phosphate using a molybdenum blue method. An ascorbic acid, standard or sample, and acidic molybdate solutions were sequentially aspirated to fill the channel forming a stack zone before flowing to the detector. Under the optimum condition, a linear calibration graph in the range of 0.1–6 mg P L −1 was obtained. The detection limit was 0.1 mg L −1 . The system is compact (5.0 mm thick, 80 mm wide × 140 mm long), durable, portable, cost-effective, and consumes little amount of chemicals (83 μL each of molybdate and ascorbic acid, 133 μL of the sample solution and 1.7 mL of water carrier/run). It was applied for the determination of phosphate content in extracted soil samples. The percent recoveries of the analysis were obtained in the range of 91.2–107.3. The results obtained agreed well with those of the batch spectrophotometric method.
format Journal
author Wanpen Khongpet
Somkid Pencharee
Chanida Puangpila
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
Jaroon Jakmunee
spellingShingle Wanpen Khongpet
Somkid Pencharee
Chanida Puangpila
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
Jaroon Jakmunee
Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
author_facet Wanpen Khongpet
Somkid Pencharee
Chanida Puangpila
Supaporn Kradtap Hartwell
Somchai Lapanantnoppakhun
Jaroon Jakmunee
author_sort Wanpen Khongpet
title Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
title_short Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
title_full Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
title_fullStr Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
title_full_unstemmed Exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
title_sort exploiting an automated microfluidic hydrodynamic sequential injection system for determination of phosphate
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85029746236&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43855
_version_ 1681422451113721856