Temperature uniformity of heated mold plate by oscillating heat pipe

© Owned by the authors, published by EDP Sciences, 2015. Uniformity of the temperature in the mold plate is of paramount important since it will affect the dimensional stability of the part produced. To provide uniform temperature to the metal plate, many factors need to be considered such as choice...

Full description

Saved in:
Bibliographic Details
Main Authors: Patrapon Kamonpet, Phrut Sakulchangsatjathai
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84976508556&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43983
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-43983
record_format dspace
spelling th-cmuir.6653943832-439832018-04-25T07:44:25Z Temperature uniformity of heated mold plate by oscillating heat pipe Patrapon Kamonpet Phrut Sakulchangsatjathai Agricultural and Biological Sciences © Owned by the authors, published by EDP Sciences, 2015. Uniformity of the temperature in the mold plate is of paramount important since it will affect the dimensional stability of the part produced. To provide uniform temperature to the metal plate, many factors need to be considered such as choice of heating technology, uniformity of a heat source, a type of control, etc. This paper aims to study the temperature uniformity of metal plate using closed-loop oscillating heat pipe (CLOHP) as a heat transfer device. The metal plates which were P-20 with the size of 306 x 130 mm2 were used. Metal plate was gouged to a depth of 3 mm for installing the CLOHP. Distances from the heating device to the metal plate surface were 5 and 10 mm. The surface temperatures of the metal plate were controlled at 80, 90, 100, 110, 120, and 130°C. Sixteen pointa of temperature were recorded. The results were then compared to those using the heat source as the cartridge heater arranged in the similar way with the same heating capacity. Once the system entered the steady state, it was found that the temperature distribution of metal plate using the CLOHP has a deviation in the range of ± 1.00°C and ± 0.94°C at the CLOHP depth of 5 mm. and 10 mm., respectively. While those of using cartridge heater deviated in the range of ± 1.35°C and ± 1.16°C. Compare to the recommended value from the ASTM Standard that the mold surface temperature need to be in the range of ± 2.0 ° C, the CLOHP shows the very promising results. 2018-01-24T04:36:46Z 2018-01-24T04:36:46Z 2015-12-11 Conference Proceeding 2261236X 2-s2.0-84976508556 10.1051/matecconf/20153403002 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84976508556&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/43983
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Agricultural and Biological Sciences
spellingShingle Agricultural and Biological Sciences
Patrapon Kamonpet
Phrut Sakulchangsatjathai
Temperature uniformity of heated mold plate by oscillating heat pipe
description © Owned by the authors, published by EDP Sciences, 2015. Uniformity of the temperature in the mold plate is of paramount important since it will affect the dimensional stability of the part produced. To provide uniform temperature to the metal plate, many factors need to be considered such as choice of heating technology, uniformity of a heat source, a type of control, etc. This paper aims to study the temperature uniformity of metal plate using closed-loop oscillating heat pipe (CLOHP) as a heat transfer device. The metal plates which were P-20 with the size of 306 x 130 mm2 were used. Metal plate was gouged to a depth of 3 mm for installing the CLOHP. Distances from the heating device to the metal plate surface were 5 and 10 mm. The surface temperatures of the metal plate were controlled at 80, 90, 100, 110, 120, and 130°C. Sixteen pointa of temperature were recorded. The results were then compared to those using the heat source as the cartridge heater arranged in the similar way with the same heating capacity. Once the system entered the steady state, it was found that the temperature distribution of metal plate using the CLOHP has a deviation in the range of ± 1.00°C and ± 0.94°C at the CLOHP depth of 5 mm. and 10 mm., respectively. While those of using cartridge heater deviated in the range of ± 1.35°C and ± 1.16°C. Compare to the recommended value from the ASTM Standard that the mold surface temperature need to be in the range of ± 2.0 ° C, the CLOHP shows the very promising results.
format Conference Proceeding
author Patrapon Kamonpet
Phrut Sakulchangsatjathai
author_facet Patrapon Kamonpet
Phrut Sakulchangsatjathai
author_sort Patrapon Kamonpet
title Temperature uniformity of heated mold plate by oscillating heat pipe
title_short Temperature uniformity of heated mold plate by oscillating heat pipe
title_full Temperature uniformity of heated mold plate by oscillating heat pipe
title_fullStr Temperature uniformity of heated mold plate by oscillating heat pipe
title_full_unstemmed Temperature uniformity of heated mold plate by oscillating heat pipe
title_sort temperature uniformity of heated mold plate by oscillating heat pipe
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84976508556&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/43983
_version_ 1681422474933174272