Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography

© 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and H...

Full description

Saved in:
Bibliographic Details
Main Authors: Sakorn Pornprasert, Manoo Punyamung
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-44334
record_format dspace
spelling th-cmuir.6653943832-443342018-04-25T07:48:20Z Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography Sakorn Pornprasert Manoo Punyamung Agricultural and Biological Sciences © 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and HPLC for the detection of Hb CS in samples with compound heterozygous of Hb CS and Hb Q-Thailand. Hemoglobin analysis was performed in blood samples of 2 patients with compound heterozygous of Hb CS and Hb Q-Thailand by using HPLC and CE. The HPLC chromatogram and CE electrophoregram of the two techniques were compared. Hb CS was not found on HPLC chromatogram while Hb QA < inf > 2 < /inf > (α < inf > 2 < /inf > < sup > QT < /sup > δ < inf > 2 < /inf > ), a derivative of Hb Q-Thailand, was presented at the retention time of 4.70–4.80 min and it was close to the retention time of Hb CS. On CE electrophoregram, Hb CS was presented at zone 2 (Z2) and it was distinctly separated from Hb QA < inf > 2 < /inf > which was presented at Z1. Therefore, CE was more efficient to the HPLC for diagnosis of compound heterozygous of Hb CS and Hb Q-Thailand. 2018-01-24T04:40:57Z 2018-01-24T04:40:57Z 2015-06-01 Journal 09740449 09714502 2-s2.0-84939887740 10.1007/s12288-014-0411-3 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Agricultural and Biological Sciences
spellingShingle Agricultural and Biological Sciences
Sakorn Pornprasert
Manoo Punyamung
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
description © 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and HPLC for the detection of Hb CS in samples with compound heterozygous of Hb CS and Hb Q-Thailand. Hemoglobin analysis was performed in blood samples of 2 patients with compound heterozygous of Hb CS and Hb Q-Thailand by using HPLC and CE. The HPLC chromatogram and CE electrophoregram of the two techniques were compared. Hb CS was not found on HPLC chromatogram while Hb QA < inf > 2 < /inf > (α < inf > 2 < /inf > < sup > QT < /sup > δ < inf > 2 < /inf > ), a derivative of Hb Q-Thailand, was presented at the retention time of 4.70–4.80 min and it was close to the retention time of Hb CS. On CE electrophoregram, Hb CS was presented at zone 2 (Z2) and it was distinctly separated from Hb QA < inf > 2 < /inf > which was presented at Z1. Therefore, CE was more efficient to the HPLC for diagnosis of compound heterozygous of Hb CS and Hb Q-Thailand.
format Journal
author Sakorn Pornprasert
Manoo Punyamung
author_facet Sakorn Pornprasert
Manoo Punyamung
author_sort Sakorn Pornprasert
title Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
title_short Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
title_full Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
title_fullStr Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
title_full_unstemmed Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
title_sort detection of compound heterozygous of hb constant spring and hb q-thailand by capillary electrophoresis and high performance liquid chromatography
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334
_version_ 1681422540263653376