Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography
© 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and H...
Saved in:
Main Authors: | , |
---|---|
Format: | Journal |
Published: |
2018
|
Subjects: | |
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-44334 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-443342018-04-25T07:48:20Z Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography Sakorn Pornprasert Manoo Punyamung Agricultural and Biological Sciences © 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and HPLC for the detection of Hb CS in samples with compound heterozygous of Hb CS and Hb Q-Thailand. Hemoglobin analysis was performed in blood samples of 2 patients with compound heterozygous of Hb CS and Hb Q-Thailand by using HPLC and CE. The HPLC chromatogram and CE electrophoregram of the two techniques were compared. Hb CS was not found on HPLC chromatogram while Hb QA < inf > 2 < /inf > (α < inf > 2 < /inf > < sup > QT < /sup > δ < inf > 2 < /inf > ), a derivative of Hb Q-Thailand, was presented at the retention time of 4.70–4.80 min and it was close to the retention time of Hb CS. On CE electrophoregram, Hb CS was presented at zone 2 (Z2) and it was distinctly separated from Hb QA < inf > 2 < /inf > which was presented at Z1. Therefore, CE was more efficient to the HPLC for diagnosis of compound heterozygous of Hb CS and Hb Q-Thailand. 2018-01-24T04:40:57Z 2018-01-24T04:40:57Z 2015-06-01 Journal 09740449 09714502 2-s2.0-84939887740 10.1007/s12288-014-0411-3 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
topic |
Agricultural and Biological Sciences |
spellingShingle |
Agricultural and Biological Sciences Sakorn Pornprasert Manoo Punyamung Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
description |
© 2014, Indian Society of Haematology & Transfusion Medicine. A capillary electrophoresis (CE) has proven to be superior to a high performance liquid chromatography (HPLC) in the detection of hemoglobin Constant Spring (Hb CS). Thus the aim of this study was to analyze the efficacy of CE and HPLC for the detection of Hb CS in samples with compound heterozygous of Hb CS and Hb Q-Thailand. Hemoglobin analysis was performed in blood samples of 2 patients with compound heterozygous of Hb CS and Hb Q-Thailand by using HPLC and CE. The HPLC chromatogram and CE electrophoregram of the two techniques were compared. Hb CS was not found on HPLC chromatogram while Hb QA < inf > 2 < /inf > (α < inf > 2 < /inf > < sup > QT < /sup > δ < inf > 2 < /inf > ), a derivative of Hb Q-Thailand, was presented at the retention time of 4.70–4.80 min and it was close to the retention time of Hb CS. On CE electrophoregram, Hb CS was presented at zone 2 (Z2) and it was distinctly separated from Hb QA < inf > 2 < /inf > which was presented at Z1. Therefore, CE was more efficient to the HPLC for diagnosis of compound heterozygous of Hb CS and Hb Q-Thailand. |
format |
Journal |
author |
Sakorn Pornprasert Manoo Punyamung |
author_facet |
Sakorn Pornprasert Manoo Punyamung |
author_sort |
Sakorn Pornprasert |
title |
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
title_short |
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
title_full |
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
title_fullStr |
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
title_full_unstemmed |
Detection of Compound Heterozygous of Hb Constant Spring and Hb Q-Thailand by Capillary Electrophoresis and High Performance Liquid Chromatography |
title_sort |
detection of compound heterozygous of hb constant spring and hb q-thailand by capillary electrophoresis and high performance liquid chromatography |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84939887740&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/44334 |
_version_ |
1681422540263653376 |