Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw

© 2014 IEEE. This paper simulates the operation of automatic circuit recloser under the system ground fault condition using MODELS language in transient digital simulation EMTP-ATPDraw. Any other recloser operation schemes such as two fast-one delay or one fast-one delay can be modeled. In this pape...

Full description

Saved in:
Bibliographic Details
Main Author: T. Thanasaksiri
Format: Conference Proceeding
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84940518705&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/44513
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-44513
record_format dspace
spelling th-cmuir.6653943832-445132018-04-25T07:51:33Z Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw T. Thanasaksiri Agricultural and Biological Sciences © 2014 IEEE. This paper simulates the operation of automatic circuit recloser under the system ground fault condition using MODELS language in transient digital simulation EMTP-ATPDraw. Any other recloser operation schemes such as two fast-one delay or one fast-one delay can be modeled. In this paper the recloser model has been tested with two fast and one time delay operation schemes for both temporary and permanent faults. The recloser model presented in this paper is the guideline for modeling the other recloser operation schemes including the other protective devices, such as fuse and over current relay which have the similar time-current characteristics. 2018-01-24T04:44:02Z 2018-01-24T04:44:02Z 2015-01-01 Conference Proceeding 21593450 21593442 2-s2.0-84940518705 10.1109/TENCON.2014.7022362 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84940518705&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/44513
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Agricultural and Biological Sciences
spellingShingle Agricultural and Biological Sciences
T. Thanasaksiri
Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
description © 2014 IEEE. This paper simulates the operation of automatic circuit recloser under the system ground fault condition using MODELS language in transient digital simulation EMTP-ATPDraw. Any other recloser operation schemes such as two fast-one delay or one fast-one delay can be modeled. In this paper the recloser model has been tested with two fast and one time delay operation schemes for both temporary and permanent faults. The recloser model presented in this paper is the guideline for modeling the other recloser operation schemes including the other protective devices, such as fuse and over current relay which have the similar time-current characteristics.
format Conference Proceeding
author T. Thanasaksiri
author_facet T. Thanasaksiri
author_sort T. Thanasaksiri
title Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
title_short Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
title_full Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
title_fullStr Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
title_full_unstemmed Modeling of recloser operation schemes under system ground fault using EMTP-ATPDraw
title_sort modeling of recloser operation schemes under system ground fault using emtp-atpdraw
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84940518705&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/44513
_version_ 1681422573401800704