Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation
Objective: The objective of this article is to evaluate the efficacy of the first trimester sonomarkers (11-14weeks) in predicting hemoglobin (Hb) Bart's disease among fetuses at risk Materials and Methods: Prospective analysis was conducted on pregnancies at risk of fetal Hb Bart's diseas...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Journal |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84896722739&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45134 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-45134 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-451342018-01-24T06:05:48Z Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation Supatra Sirichotiyakul Suchaya Luewan Kasemsri Srisupundit Fuanglada Tongprasert Theera Tongsong Objective: The objective of this article is to evaluate the efficacy of the first trimester sonomarkers (11-14weeks) in predicting hemoglobin (Hb) Bart's disease among fetuses at risk Materials and Methods: Prospective analysis was conducted on pregnancies at risk of fetal Hb Bart's disease at 11 to 14weeks of gestation. Sonographic markers including cardiothoracic (CT) ratio, peak systolic velocity of the middle cerebral artery (MCA-PSV), placental thickness, and nuchal translucency were prospectively assessed and recorded. The definite diagnosis of fetal Hb Bart's disease was based on DNA analysis (chorionic villus sampling) or subsequent fetal Hb typing (high-performance liquid chromatography; cordocentesis). Results: Among 104 pregnancies at risk with complete sonographic assessment at 11 to 14weeks of gestation, 30 fetuses were finally proven to be affected. The CT ratio gave the highest sensitivity, 93.3%, with specificity of 93.2%, followed by placental thickness and MCA-PSV, respectively. Nuchal translucency had a very low sensitivity of 16.7%. The combination of CT ratio and MCA-PSV increased the sensitivity to 96.7% but somewhat compromise specificity. Conclusions: At 11 to 14weeks of gestation, sonographic markers can effectively differentiate affected from unaffected pregnancies. The most sensitive marker was CT ratio plus MCA-PSV. Of couples at risk with no any sonographic markers, the risk of having an affected fetus is nearly eliminated. © 2013 John Wiley & Sons, Ltd. 2018-01-24T06:05:48Z 2018-01-24T06:05:48Z 2014-03-01 Journal 10970223 01973851 2-s2.0-84896722739 10.1002/pd.4293 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84896722739&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45134 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
Objective: The objective of this article is to evaluate the efficacy of the first trimester sonomarkers (11-14weeks) in predicting hemoglobin (Hb) Bart's disease among fetuses at risk Materials and Methods: Prospective analysis was conducted on pregnancies at risk of fetal Hb Bart's disease at 11 to 14weeks of gestation. Sonographic markers including cardiothoracic (CT) ratio, peak systolic velocity of the middle cerebral artery (MCA-PSV), placental thickness, and nuchal translucency were prospectively assessed and recorded. The definite diagnosis of fetal Hb Bart's disease was based on DNA analysis (chorionic villus sampling) or subsequent fetal Hb typing (high-performance liquid chromatography; cordocentesis). Results: Among 104 pregnancies at risk with complete sonographic assessment at 11 to 14weeks of gestation, 30 fetuses were finally proven to be affected. The CT ratio gave the highest sensitivity, 93.3%, with specificity of 93.2%, followed by placental thickness and MCA-PSV, respectively. Nuchal translucency had a very low sensitivity of 16.7%. The combination of CT ratio and MCA-PSV increased the sensitivity to 96.7% but somewhat compromise specificity. Conclusions: At 11 to 14weeks of gestation, sonographic markers can effectively differentiate affected from unaffected pregnancies. The most sensitive marker was CT ratio plus MCA-PSV. Of couples at risk with no any sonographic markers, the risk of having an affected fetus is nearly eliminated. © 2013 John Wiley & Sons, Ltd. |
format |
Journal |
author |
Supatra Sirichotiyakul Suchaya Luewan Kasemsri Srisupundit Fuanglada Tongprasert Theera Tongsong |
spellingShingle |
Supatra Sirichotiyakul Suchaya Luewan Kasemsri Srisupundit Fuanglada Tongprasert Theera Tongsong Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
author_facet |
Supatra Sirichotiyakul Suchaya Luewan Kasemsri Srisupundit Fuanglada Tongprasert Theera Tongsong |
author_sort |
Supatra Sirichotiyakul |
title |
Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
title_short |
Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
title_full |
Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
title_fullStr |
Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
title_full_unstemmed |
Prenatal ultrasound evaluation of fetal Hb Bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
title_sort |
prenatal ultrasound evaluation of fetal hb bart's disease among pregnancies at risk at 11 to 14weeks of gestation |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84896722739&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45134 |
_version_ |
1681422688783958016 |