Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables
In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45323 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-45323 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-453232018-01-24T06:08:32Z Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables P. Thararak P. Jirapong P. Jan-Ngoen In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of protection schemes including metal oxide surge arresters and controlled switching are analyzed for controlling switching overvoltages during cable energization. The digital computer simulations are made using PSCAD/EMTDC software. Test results show that the overvoltage values at the sending and receiving ends from the cable energization without surge arresters and controlled switching of circuit breaker can reach up to 1.6-2.0 p.u. In addition, the switching overvoltages can be mitigated by the provision of surge arresters at the two line terminations. Additional limitation of these overvoltages, controlled switching involving individual closing of each phase in the circuit breaker at the optimal point-of-wave can be used. © 2014 Asian Institute of Technology. 2018-01-24T06:08:32Z 2018-01-24T06:08:32Z 2014-01-01 Conference Proceeding 2-s2.0-84903691929 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45323 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
In this paper, switching overvoltages analysis based on the statistical study approach according to IEC 6007 Insulation Co-ordination are analyzed for the energization of the connected 115 kV underground and submarine cables from Khanom power plant to Samui Island substation. Comparative analysis of protection schemes including metal oxide surge arresters and controlled switching are analyzed for controlling switching overvoltages during cable energization. The digital computer simulations are made using PSCAD/EMTDC software. Test results show that the overvoltage values at the sending and receiving ends from the cable energization without surge arresters and controlled switching of circuit breaker can reach up to 1.6-2.0 p.u. In addition, the switching overvoltages can be mitigated by the provision of surge arresters at the two line terminations. Additional limitation of these overvoltages, controlled switching involving individual closing of each phase in the circuit breaker at the optimal point-of-wave can be used. © 2014 Asian Institute of Technology. |
format |
Conference Proceeding |
author |
P. Thararak P. Jirapong P. Jan-Ngoen |
spellingShingle |
P. Thararak P. Jirapong P. Jan-Ngoen Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
author_facet |
P. Thararak P. Jirapong P. Jan-Ngoen |
author_sort |
P. Thararak |
title |
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
title_short |
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
title_full |
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
title_fullStr |
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
title_full_unstemmed |
Analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
title_sort |
analysis of switching transient overvoltages and protection techniques for the energization of the connected 115 kv underground and submarine cables |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84903691929&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45323 |
_version_ |
1681422723890282496 |