Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump
© 2014 The Authors. Published by Elsevier Ltd. In this study, simulation and experiment studies of a 10 kW solar H 2 O-LiBr absorption heat transformer (AHT) integrating with a two-stage vapor compression heat pump (VCHP) were carried out. The whole system was named as compression/absorption heat tr...
Saved in:
Main Authors: | , |
---|---|
Format: | Journal |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84916603229&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45554 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-45554 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-455542018-01-24T06:12:09Z Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump Nattaporn Chaiyat Tanongkiat Kiatsiriroat © 2014 The Authors. Published by Elsevier Ltd. In this study, simulation and experiment studies of a 10 kW solar H 2 O-LiBr absorption heat transformer (AHT) integrating with a two-stage vapor compression heat pump (VCHP) were carried out. The whole system was named as compression/absorption heat transformer (CAHT). The VCHP was used to recover rejected heat at the AHT condenser which was transferred back to the AHT evaporator at a higher temperature. The AHT unit took solar heat from a set of flat-plate solar collectors in parallel connection. R-134a and R-123 were refrigerants in the VCHP cycle. From the simulation, the total cycle coefficient (COP) of the solar-CAHT was 0.71 compared with 0.49 of the normal solar-AHT. From the experiment, the total cycle COPs of the solar-CAHT and the solar-AHT were 0.62 and 0.39, respectively. The experimental results were lower than those of the simulated models due to the oversize of the experimental compressor. The annual expense of the solar-CAHT was found to be 5113 USD which was lower than 5418 USD of the solar-AHT. So it could be concluded that the modified unit was beneficial than the normal unit in terms of energy efficiency and economic expense. 2018-01-24T06:12:09Z 2018-01-24T06:12:09Z 2014-01-01 Journal 2214157X 2-s2.0-84916603229 10.1016/j.csite.2014.09.007 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84916603229&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45554 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
© 2014 The Authors. Published by Elsevier Ltd. In this study, simulation and experiment studies of a 10 kW solar H 2 O-LiBr absorption heat transformer (AHT) integrating with a two-stage vapor compression heat pump (VCHP) were carried out. The whole system was named as compression/absorption heat transformer (CAHT). The VCHP was used to recover rejected heat at the AHT condenser which was transferred back to the AHT evaporator at a higher temperature. The AHT unit took solar heat from a set of flat-plate solar collectors in parallel connection. R-134a and R-123 were refrigerants in the VCHP cycle. From the simulation, the total cycle coefficient (COP) of the solar-CAHT was 0.71 compared with 0.49 of the normal solar-AHT. From the experiment, the total cycle COPs of the solar-CAHT and the solar-AHT were 0.62 and 0.39, respectively. The experimental results were lower than those of the simulated models due to the oversize of the experimental compressor. The annual expense of the solar-CAHT was found to be 5113 USD which was lower than 5418 USD of the solar-AHT. So it could be concluded that the modified unit was beneficial than the normal unit in terms of energy efficiency and economic expense. |
format |
Journal |
author |
Nattaporn Chaiyat Tanongkiat Kiatsiriroat |
spellingShingle |
Nattaporn Chaiyat Tanongkiat Kiatsiriroat Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
author_facet |
Nattaporn Chaiyat Tanongkiat Kiatsiriroat |
author_sort |
Nattaporn Chaiyat |
title |
Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
title_short |
Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
title_full |
Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
title_fullStr |
Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
title_full_unstemmed |
Simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
title_sort |
simulation and experimental study of solar-absorption heat transformer integrating with two-stage high temperature vapor compression heat pump |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84916603229&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/45554 |
_version_ |
1681422767045476352 |