Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients

© 2017 Tan et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Purpose To document the diurnal intraocular pr...

Full description

Saved in:
Bibliographic Details
Main Authors: Shaoying Tan, Nafees Baig, Linda Hansapinyo, Vishal Jhanji, Shihui Wei, Clement C. Tham
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016146887&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/46245
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-46245
record_format dspace
spelling th-cmuir.6653943832-462452018-04-25T07:27:13Z Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients Shaoying Tan Nafees Baig Linda Hansapinyo Vishal Jhanji Shihui Wei Clement C. Tham Biochemistry, Genetics and Molecular Biology Agricultural and Biological Sciences © 2017 Tan et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Purpose To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment. Patients and methods Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG) patients with no previous eye surgery were recruited. Diurnal IOP was measured 5 times per day at four-hourly intervals from 08:00 to 24:00 for 1 week in patients' study eye using rebound tonometry in a non-clinic environment. The diurnal IOP profiles were compared between PACG and POAG eyes. Results For both PACG and POAG eyes, mean patient-measured IOP was highest in the morning, gradually decreased over the course of a day, and was lowest by midnight (p < 0.001). The diurnal IOP fluctuation ± 1 standard deviation (SD), as documented by SD in daily IOP values, was lower in PACG group (1.6 ± 1.1 mmHg) than in POAG group (2.0 ± 1.2 mmHg; p = 0.049). The mean trough IOP ± 1 SD was higher in PACG group (12.9 ± 2.8 mmHg), compared to POAG group (11.5 ± 3.8 mmHg; p = 0.041). The mean IOP level at midnight ± 1 SD in PACG group (14.0 ± 3.2 mmHg) was higher than that in POAG group (12.1 ± 3.7 mmHg; p = 0.013). Conclusions IOP in primary glaucoma patients was highest in the morning, and decreased over the course of a day in non-clinic environment. Treated diurnal IOP fluctuation seemed to be greater in POAG than PACG eyes. 2018-04-25T06:51:51Z 2018-04-25T06:51:51Z 2017-03-01 Journal 19326203 2-s2.0-85016146887 10.1371/journal.pone.0173905 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016146887&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/46245
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Agricultural and Biological Sciences
spellingShingle Biochemistry, Genetics and Molecular Biology
Agricultural and Biological Sciences
Shaoying Tan
Nafees Baig
Linda Hansapinyo
Vishal Jhanji
Shihui Wei
Clement C. Tham
Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
description © 2017 Tan et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Purpose To document the diurnal intraocular pressure (IOP) profile with rebound tonometry performed by primary glaucoma patients in non-clinic environment. Patients and methods Fifty-three medically-treated eyes of 31 primary angle closure glaucoma (PACG) and 22 primary open angle glaucoma (POAG) patients with no previous eye surgery were recruited. Diurnal IOP was measured 5 times per day at four-hourly intervals from 08:00 to 24:00 for 1 week in patients' study eye using rebound tonometry in a non-clinic environment. The diurnal IOP profiles were compared between PACG and POAG eyes. Results For both PACG and POAG eyes, mean patient-measured IOP was highest in the morning, gradually decreased over the course of a day, and was lowest by midnight (p < 0.001). The diurnal IOP fluctuation ± 1 standard deviation (SD), as documented by SD in daily IOP values, was lower in PACG group (1.6 ± 1.1 mmHg) than in POAG group (2.0 ± 1.2 mmHg; p = 0.049). The mean trough IOP ± 1 SD was higher in PACG group (12.9 ± 2.8 mmHg), compared to POAG group (11.5 ± 3.8 mmHg; p = 0.041). The mean IOP level at midnight ± 1 SD in PACG group (14.0 ± 3.2 mmHg) was higher than that in POAG group (12.1 ± 3.7 mmHg; p = 0.013). Conclusions IOP in primary glaucoma patients was highest in the morning, and decreased over the course of a day in non-clinic environment. Treated diurnal IOP fluctuation seemed to be greater in POAG than PACG eyes.
format Journal
author Shaoying Tan
Nafees Baig
Linda Hansapinyo
Vishal Jhanji
Shihui Wei
Clement C. Tham
author_facet Shaoying Tan
Nafees Baig
Linda Hansapinyo
Vishal Jhanji
Shihui Wei
Clement C. Tham
author_sort Shaoying Tan
title Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_short Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_full Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_fullStr Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_full_unstemmed Comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
title_sort comparison of self-measured diurnal intraocular pressure profiles using rebound tonometry between primary angle closure glaucoma and primary open angle glaucoma patients
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85016146887&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/46245
_version_ 1681422838450356224