Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration
© Copyright 2017, American Society of Health-System Pharmacists, Inc. Purpose: The compatibility of colistin with other antibiotics at concentrations commonly used in intensive care units was studied. Methods: A vial of colistin was dissolved in sterile water for injection. The reconstituted solutio...
Saved in:
Main Author: | |
---|---|
Format: | Journal |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85024371235&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47099 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-47099 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-470992018-04-25T07:22:32Z Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration Wasan Katip © Copyright 2017, American Society of Health-System Pharmacists, Inc. Purpose: The compatibility of colistin with other antibiotics at concentrations commonly used in intensive care units was studied. Methods: A vial of colistin was dissolved in sterile water for injection. The reconstituted solution (colistin base 75 mg/mL) was then diluted in 0.9% sodium chloride injection in polyvinyl chloride (PVC) infusion bag to give a total volume of 100 mL (colistin 1.5 mg/mL). Secondary drugs, including cefoperazone-sulbactam, ceftazidime, ertapenem, fosfomycin, imipenem-cilastatin, linezolid, meropenem, piperacillin-tazobactam, and vancomycin, were reconstituted if necessary and then diluted in 0.9% sodium chloride injection in PVC infusion bags to give final study concentrations of one-hundredth of their initial concentrations. The admixtures were collected in beakers at the end of the i.v. line and stored at 26 °C under constant fluorescent light throughout the study. Compatibility was assessed visually during delivery of each drug pair at time 0 and at 1 hour after starting the infusion. Compatibility was defined as the absence of visually detected particulate formation, haze, precipitation, color change, or gas evolution. Each combination was tested in triplicate. Results: No particulate formation or other evidence of incompatibility was found in any of the studied drug combinations when observed immediately after mixing or at 1 hour. No particulate matter was observed with the unaided eyes, during microscopic evaluation, or against black and white backgrounds. Conclusion: Colistin 1.5 mg/mL was visually compatible with single concentrations of 9 other antimicrobial products during simulated Y-site injection at 26 °C without light protection for at least 1 hour. 2018-04-25T07:22:32Z 2018-04-25T07:22:32Z 2017-07-15 Journal 15352900 10792082 2-s2.0-85024371235 10.2146/ajhp160216 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85024371235&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47099 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
© Copyright 2017, American Society of Health-System Pharmacists, Inc. Purpose: The compatibility of colistin with other antibiotics at concentrations commonly used in intensive care units was studied. Methods: A vial of colistin was dissolved in sterile water for injection. The reconstituted solution (colistin base 75 mg/mL) was then diluted in 0.9% sodium chloride injection in polyvinyl chloride (PVC) infusion bag to give a total volume of 100 mL (colistin 1.5 mg/mL). Secondary drugs, including cefoperazone-sulbactam, ceftazidime, ertapenem, fosfomycin, imipenem-cilastatin, linezolid, meropenem, piperacillin-tazobactam, and vancomycin, were reconstituted if necessary and then diluted in 0.9% sodium chloride injection in PVC infusion bags to give final study concentrations of one-hundredth of their initial concentrations. The admixtures were collected in beakers at the end of the i.v. line and stored at 26 °C under constant fluorescent light throughout the study. Compatibility was assessed visually during delivery of each drug pair at time 0 and at 1 hour after starting the infusion. Compatibility was defined as the absence of visually detected particulate formation, haze, precipitation, color change, or gas evolution. Each combination was tested in triplicate. Results: No particulate formation or other evidence of incompatibility was found in any of the studied drug combinations when observed immediately after mixing or at 1 hour. No particulate matter was observed with the unaided eyes, during microscopic evaluation, or against black and white backgrounds. Conclusion: Colistin 1.5 mg/mL was visually compatible with single concentrations of 9 other antimicrobial products during simulated Y-site injection at 26 °C without light protection for at least 1 hour. |
format |
Journal |
author |
Wasan Katip |
spellingShingle |
Wasan Katip Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
author_facet |
Wasan Katip |
author_sort |
Wasan Katip |
title |
Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
title_short |
Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
title_full |
Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
title_fullStr |
Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
title_full_unstemmed |
Visual compatibility of colistin injection with other antibiotics during simulated Y-site administration |
title_sort |
visual compatibility of colistin injection with other antibiotics during simulated y-site administration |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85024371235&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47099 |
_version_ |
1681422997905211392 |