Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography

© 2016, Springer Science+Business Media Dordrecht. To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate n...

Full description

Saved in:
Bibliographic Details
Main Authors: Carlos Collet, Yohei Sotomi, Rafael Cavalcante, Taku Asano, Yosuke Miyazaki, Erhan Tenekecioglu, Pieter Kistlaar, Yaping Zeng, Pannipa Suwanasson, Robbert J. de Winter, Koen Nieman, Patrick W. Serruys, Yoshinobu Onuma
Format: Journal
Published: 2018
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84997719833&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47232
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-47232
record_format dspace
spelling th-cmuir.6653943832-472322018-04-25T07:27:15Z Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography Carlos Collet Yohei Sotomi Rafael Cavalcante Taku Asano Yosuke Miyazaki Erhan Tenekecioglu Pieter Kistlaar Yaping Zeng Pannipa Suwanasson Robbert J. de Winter Koen Nieman Patrick W. Serruys Yoshinobu Onuma © 2016, Springer Science+Business Media Dordrecht. To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate non-invasively the coronary lumen with coronary CTA. In the ABSORB first-in-man studies, coronary CTA was shown to be feasible for quantitative luminal assessment. Nevertheless, a comparison with an intravascular modality with higher resolution has never been performed. In the ABSORB Cohort B trial, 101 patient with non-complex lesions were treated with the fully biodegradable vascular scaffold. For this analysis, all patients who underwent coronary CTA at 18 months and OCT within ±180 days were included. Coronary CTA and OCT data were analysed at an independent core laboratory for quantitative cross-sectional luminal dimensions. The primary objective was the accuracy and precision of coronary CTA for in-scaffold minimal lumen area assessment, with OCT as a reference. Among the 101 patients of the ABSORB Cohort B trial, 35 underwent both OCT and coronary CTA. The feasibility of quantitative evaluation was 74%. In the scaffolded segment, coronary CTA underestimated minimal lumen area by 9.8% (accuracy 0.39 mm 2 , precision 1.0 mm 2 , 95% limits of agreement −1.71 to 2.50 mm 2 ). A similar level of agreement was observed in the non-scaffolded segment. Compared to OCT, coronary CTA appears to be accurate for the estimation of in-scaffold luminal areas, with no difference compared to the non-scaffolded region. 2018-04-25T07:27:15Z 2018-04-25T07:27:15Z 2017-03-01 Journal 15730743 15695794 2-s2.0-84997719833 10.1007/s10554-016-1018-6 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84997719833&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47232
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description © 2016, Springer Science+Business Media Dordrecht. To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate non-invasively the coronary lumen with coronary CTA. In the ABSORB first-in-man studies, coronary CTA was shown to be feasible for quantitative luminal assessment. Nevertheless, a comparison with an intravascular modality with higher resolution has never been performed. In the ABSORB Cohort B trial, 101 patient with non-complex lesions were treated with the fully biodegradable vascular scaffold. For this analysis, all patients who underwent coronary CTA at 18 months and OCT within ±180 days were included. Coronary CTA and OCT data were analysed at an independent core laboratory for quantitative cross-sectional luminal dimensions. The primary objective was the accuracy and precision of coronary CTA for in-scaffold minimal lumen area assessment, with OCT as a reference. Among the 101 patients of the ABSORB Cohort B trial, 35 underwent both OCT and coronary CTA. The feasibility of quantitative evaluation was 74%. In the scaffolded segment, coronary CTA underestimated minimal lumen area by 9.8% (accuracy 0.39 mm 2 , precision 1.0 mm 2 , 95% limits of agreement −1.71 to 2.50 mm 2 ). A similar level of agreement was observed in the non-scaffolded segment. Compared to OCT, coronary CTA appears to be accurate for the estimation of in-scaffold luminal areas, with no difference compared to the non-scaffolded region.
format Journal
author Carlos Collet
Yohei Sotomi
Rafael Cavalcante
Taku Asano
Yosuke Miyazaki
Erhan Tenekecioglu
Pieter Kistlaar
Yaping Zeng
Pannipa Suwanasson
Robbert J. de Winter
Koen Nieman
Patrick W. Serruys
Yoshinobu Onuma
spellingShingle Carlos Collet
Yohei Sotomi
Rafael Cavalcante
Taku Asano
Yosuke Miyazaki
Erhan Tenekecioglu
Pieter Kistlaar
Yaping Zeng
Pannipa Suwanasson
Robbert J. de Winter
Koen Nieman
Patrick W. Serruys
Yoshinobu Onuma
Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
author_facet Carlos Collet
Yohei Sotomi
Rafael Cavalcante
Taku Asano
Yosuke Miyazaki
Erhan Tenekecioglu
Pieter Kistlaar
Yaping Zeng
Pannipa Suwanasson
Robbert J. de Winter
Koen Nieman
Patrick W. Serruys
Yoshinobu Onuma
author_sort Carlos Collet
title Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
title_short Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
title_full Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
title_fullStr Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
title_full_unstemmed Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
title_sort accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84997719833&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47232
_version_ 1681423022686208000