Accuracy of cone beam computed tomography for dental implant treatment planning

This study evaluated the accuracy of cone beam computed tomography (CBCT) measurements using post-surgical, implant placement, CBCT images by measuring the length and width of implants on CBCT images and comparing these measurements to the actual sizes of the implants, as well as investigated critic...

Full description

Saved in:
Bibliographic Details
Main Authors: Pathawee Khongkhunthian, Kanoknual Jomjunyong, Peter A. Reichart
Format: Journal
Published: 2018
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85014439596&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47300
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-47300
record_format dspace
spelling th-cmuir.6653943832-473002018-04-25T07:31:09Z Accuracy of cone beam computed tomography for dental implant treatment planning Pathawee Khongkhunthian Kanoknual Jomjunyong Peter A. Reichart This study evaluated the accuracy of cone beam computed tomography (CBCT) measurements using post-surgical, implant placement, CBCT images by measuring the length and width of implants on CBCT images and comparing these measurements to the actual sizes of the implants, as well as investigated critical anatomical structure injuries after using CBCT for planning. Ninety-six post-operative CBCT scans of 171 dental implants, placed between October 2012 and March 2015, were included in the study. Each implant was measured on the CBCT images for both diameter and length, using the measuring tool in the CBCT software. The measured values were compared with the actual implant diameters and lengths and calculated as a percentage of error. The mean percentage of error was 2.26%. There were no significant differences in percentage of error between implant size, implant diameters, implant positions, upper jaw, lower jaw, anterior area, or posterior area (p > 0.05). Anatomical structure injuries were not found post-operatively. The accuracy of CBCT used for measurement in this study was 97.74%, and comparable to that reported for other commercial CBCT machines. The use of CBCT for implant planning can avoid anatomical structure injuries. 2018-04-25T07:31:09Z 2018-04-25T07:31:09Z 2017-01-01 Journal 16851994 2-s2.0-85014439596 10.12982/cmujns.2017.0005 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85014439596&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47300
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description This study evaluated the accuracy of cone beam computed tomography (CBCT) measurements using post-surgical, implant placement, CBCT images by measuring the length and width of implants on CBCT images and comparing these measurements to the actual sizes of the implants, as well as investigated critical anatomical structure injuries after using CBCT for planning. Ninety-six post-operative CBCT scans of 171 dental implants, placed between October 2012 and March 2015, were included in the study. Each implant was measured on the CBCT images for both diameter and length, using the measuring tool in the CBCT software. The measured values were compared with the actual implant diameters and lengths and calculated as a percentage of error. The mean percentage of error was 2.26%. There were no significant differences in percentage of error between implant size, implant diameters, implant positions, upper jaw, lower jaw, anterior area, or posterior area (p > 0.05). Anatomical structure injuries were not found post-operatively. The accuracy of CBCT used for measurement in this study was 97.74%, and comparable to that reported for other commercial CBCT machines. The use of CBCT for implant planning can avoid anatomical structure injuries.
format Journal
author Pathawee Khongkhunthian
Kanoknual Jomjunyong
Peter A. Reichart
spellingShingle Pathawee Khongkhunthian
Kanoknual Jomjunyong
Peter A. Reichart
Accuracy of cone beam computed tomography for dental implant treatment planning
author_facet Pathawee Khongkhunthian
Kanoknual Jomjunyong
Peter A. Reichart
author_sort Pathawee Khongkhunthian
title Accuracy of cone beam computed tomography for dental implant treatment planning
title_short Accuracy of cone beam computed tomography for dental implant treatment planning
title_full Accuracy of cone beam computed tomography for dental implant treatment planning
title_fullStr Accuracy of cone beam computed tomography for dental implant treatment planning
title_full_unstemmed Accuracy of cone beam computed tomography for dental implant treatment planning
title_sort accuracy of cone beam computed tomography for dental implant treatment planning
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85014439596&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47300
_version_ 1681423035292188672