Improving the lightning performance of overhead lines applying additional underbuilt shield wire
This paper analyzes the lightning performance of 22 kV single and double circuits overhead distribution lines by means of installation the additional underbuilt shield wire. The simulations have been implemented using ATPDraw and calculations by applying equations taken from IEEE std. 1410-2010. The...
Saved in:
Main Author: | |
---|---|
Format: | Conference Proceeding |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84883101785&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47656 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-47656 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-476562018-04-25T08:42:29Z Improving the lightning performance of overhead lines applying additional underbuilt shield wire T. Thanasaksiri This paper analyzes the lightning performance of 22 kV single and double circuits overhead distribution lines by means of installation the additional underbuilt shield wire. The simulations have been implemented using ATPDraw and calculations by applying equations taken from IEEE std. 1410-2010. The total number of flashovers, direct stroke and induced voltage flashovers, have been evaluated. The additional underbuilt shield wire sizes and the placement locations have been determined. © 2013 IEEE. 2018-04-25T08:42:29Z 2018-04-25T08:42:29Z 2013-09-02 Conference Proceeding 2-s2.0-84883101785 10.1109/ECTICon.2013.6559510 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84883101785&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47656 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
This paper analyzes the lightning performance of 22 kV single and double circuits overhead distribution lines by means of installation the additional underbuilt shield wire. The simulations have been implemented using ATPDraw and calculations by applying equations taken from IEEE std. 1410-2010. The total number of flashovers, direct stroke and induced voltage flashovers, have been evaluated. The additional underbuilt shield wire sizes and the placement locations have been determined. © 2013 IEEE. |
format |
Conference Proceeding |
author |
T. Thanasaksiri |
spellingShingle |
T. Thanasaksiri Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
author_facet |
T. Thanasaksiri |
author_sort |
T. Thanasaksiri |
title |
Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
title_short |
Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
title_full |
Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
title_fullStr |
Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
title_full_unstemmed |
Improving the lightning performance of overhead lines applying additional underbuilt shield wire |
title_sort |
improving the lightning performance of overhead lines applying additional underbuilt shield wire |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84883101785&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47656 |
_version_ |
1681423102303535104 |