Flattening effect on heat transfer characteristics of a sintered-wick heat pipe
The effect of pipe flattening on heat transfer characteristics and the internal phenomena of a sintered-wick heat pipe has been investigated by using three-dimensional Finite Element Method. The calculation domains were focused at three important regions, i.e., vapor core, wick and wall. The Cartesi...
Saved in:
Main Authors: | , , |
---|---|
Format: | Journal |
Published: |
2018
|
Online Access: | https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84879976207&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47810 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Chiang Mai University |
id |
th-cmuir.6653943832-47810 |
---|---|
record_format |
dspace |
spelling |
th-cmuir.6653943832-478102018-04-25T08:44:14Z Flattening effect on heat transfer characteristics of a sintered-wick heat pipe Weeranut Intagun Pradit Terdtoon Phurt Sakulchangsatjatai The effect of pipe flattening on heat transfer characteristics and the internal phenomena of a sintered-wick heat pipe has been investigated by using three-dimensional Finite Element Method. The calculation domains were focused at three important regions, i.e., vapor core, wick and wall. The Cartesian coordinates and the three-dimensional tetrahedral elements were applied in this model. The selected total elements were 638,400 to ensure the accuracy. The original diameter and total length of heat pipe were 6 mm and 200 mm, respectively. The composite wick made from sintered copper powder and grooved copper pipe was applied with water as working fluid. The vapor flow was assumed to be laminar and incompressible. The predicted results from the program were validated with the experimental results conducted with all similar controlled parameters. It was found that the predicted wall temperature and thermal resistance agreed well with the experimental data with the standard deviations of ±5.95 and ±32.85%, respectively. Furthermore, the overall thermal resistances of the tubular heat pipes (original diameter of 6 mm), which were flattened into the final thickness of 4.0 and 3.0 mm, decreased from 0.91 to 0.83°C/W due to an increase of the contacted surface for heat transfer surface. However, the overall thermal resistance of a flattened heat pipe with the final thickness of 2.5 mm increased to 0.88°C/W, resulting from drastic increase of pressure drop in narrower vapor core. The pivotal final thickness of flattened heat pipe, which is the minimum thickness of pipe to be flattened, has been analyzed to be 2.75 mm (about 45% from original diameter). © 2013 Science Publication. 2018-04-25T08:44:14Z 2018-04-25T08:44:14Z 2013-07-15 Journal 15543641 15469239 2-s2.0-84879976207 10.3844/ajassp.2013.760.766 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84879976207&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47810 |
institution |
Chiang Mai University |
building |
Chiang Mai University Library |
country |
Thailand |
collection |
CMU Intellectual Repository |
description |
The effect of pipe flattening on heat transfer characteristics and the internal phenomena of a sintered-wick heat pipe has been investigated by using three-dimensional Finite Element Method. The calculation domains were focused at three important regions, i.e., vapor core, wick and wall. The Cartesian coordinates and the three-dimensional tetrahedral elements were applied in this model. The selected total elements were 638,400 to ensure the accuracy. The original diameter and total length of heat pipe were 6 mm and 200 mm, respectively. The composite wick made from sintered copper powder and grooved copper pipe was applied with water as working fluid. The vapor flow was assumed to be laminar and incompressible. The predicted results from the program were validated with the experimental results conducted with all similar controlled parameters. It was found that the predicted wall temperature and thermal resistance agreed well with the experimental data with the standard deviations of ±5.95 and ±32.85%, respectively. Furthermore, the overall thermal resistances of the tubular heat pipes (original diameter of 6 mm), which were flattened into the final thickness of 4.0 and 3.0 mm, decreased from 0.91 to 0.83°C/W due to an increase of the contacted surface for heat transfer surface. However, the overall thermal resistance of a flattened heat pipe with the final thickness of 2.5 mm increased to 0.88°C/W, resulting from drastic increase of pressure drop in narrower vapor core. The pivotal final thickness of flattened heat pipe, which is the minimum thickness of pipe to be flattened, has been analyzed to be 2.75 mm (about 45% from original diameter). © 2013 Science Publication. |
format |
Journal |
author |
Weeranut Intagun Pradit Terdtoon Phurt Sakulchangsatjatai |
spellingShingle |
Weeranut Intagun Pradit Terdtoon Phurt Sakulchangsatjatai Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
author_facet |
Weeranut Intagun Pradit Terdtoon Phurt Sakulchangsatjatai |
author_sort |
Weeranut Intagun |
title |
Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
title_short |
Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
title_full |
Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
title_fullStr |
Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
title_full_unstemmed |
Flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
title_sort |
flattening effect on heat transfer characteristics of a sintered-wick heat pipe |
publishDate |
2018 |
url |
https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84879976207&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47810 |
_version_ |
1681423131926855680 |