Intraoperative panoramic image using alignment grid, is it accurate?

Background: Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. Objectives: To comp...

Full description

Saved in:
Bibliographic Details
Main Authors: T. Apivatthakakul, M. Duanghakrung, S. Luevitoonvechkit, S. Patumasutra
Format: Journal
Published: 2018
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880152867&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47823
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-47823
record_format dspace
spelling th-cmuir.6653943832-478232018-04-25T08:44:25Z Intraoperative panoramic image using alignment grid, is it accurate? T. Apivatthakakul M. Duanghakrung S. Luevitoonvechkit S. Patumasutra Background: Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. Objectives: To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Materials and methods: Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. Results: The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Conclusion: Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays. © 2013 Springer-Verlag Berlin Heidelberg. 2018-04-25T08:44:25Z 2018-04-25T08:44:25Z 2013-07-01 Journal 14343916 09368051 2-s2.0-84880152867 10.1007/s00402-013-1765-y https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880152867&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/47823
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description Background: Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. Objectives: To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Materials and methods: Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. Results: The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Conclusion: Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays. © 2013 Springer-Verlag Berlin Heidelberg.
format Journal
author T. Apivatthakakul
M. Duanghakrung
S. Luevitoonvechkit
S. Patumasutra
spellingShingle T. Apivatthakakul
M. Duanghakrung
S. Luevitoonvechkit
S. Patumasutra
Intraoperative panoramic image using alignment grid, is it accurate?
author_facet T. Apivatthakakul
M. Duanghakrung
S. Luevitoonvechkit
S. Patumasutra
author_sort T. Apivatthakakul
title Intraoperative panoramic image using alignment grid, is it accurate?
title_short Intraoperative panoramic image using alignment grid, is it accurate?
title_full Intraoperative panoramic image using alignment grid, is it accurate?
title_fullStr Intraoperative panoramic image using alignment grid, is it accurate?
title_full_unstemmed Intraoperative panoramic image using alignment grid, is it accurate?
title_sort intraoperative panoramic image using alignment grid, is it accurate?
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84880152867&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/47823
_version_ 1681423134392057856