Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report

Purpose: The aims of this anatomical study were to evaluate the feasibility of minimally invasive plate osteosynthesis (MIPO) using a posterolateral approach in distal tibial fractures and to study the relationship between neurovascular structures and the plate. Methods: Two separate incisions, one...

Full description

Saved in:
Bibliographic Details
Main Authors: Apipop Kritsaneephaiboon, Tanawat Vaseenon, Boonsin Tangtrakulwanich
Format: Journal
Published: 2018
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84871923836&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48276
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-48276
record_format dspace
spelling th-cmuir.6653943832-482762018-04-25T08:50:00Z Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report Apipop Kritsaneephaiboon Tanawat Vaseenon Boonsin Tangtrakulwanich Purpose: The aims of this anatomical study were to evaluate the feasibility of minimally invasive plate osteosynthesis (MIPO) using a posterolateral approach in distal tibial fractures and to study the relationship between neurovascular structures and the plate. Methods: Two separate incisions, one proximal and one distal, were made on the posterolateral aspect of ten cadaveric legs in the prone position. A 14-hole contralateral anterolateral distal tibial locking plate was inserted into the submuscular tunnel using a posterolateral approach, and one screw was fixed on each side of the proximal and distal tibia. The MIPO tunnel was then explored to identify the relationship between neurovascular bundles and plate. Results: For the proximal incision, retraction of the flexor hallucis longus and the tibialis posterior muscles medially was very important because it could protect the posterior tibial artery and the tibial nerve during plating. The sural nerve and lesser saphenous vein were easily identified and retracted in the superficial layer of the distal incision. In addition, we achieved satisfactory outcomes after using this MIPO technique in one patient. Conclusion: Based on the results of our study, it seems that using the MIPO technique through a posterolateral approach should be a reasonable and safe treatment option for distal tibial fractures, especially when the anterior soft tissue is compromised. However, studies with a higher level of evidence should be done in more patients to confirm the clinical safety of using this technique. © 2012 Springer-Verlag Berlin Heidelberg. 2018-04-25T08:50:00Z 2018-04-25T08:50:00Z 2013-01-01 Journal 14325195 03412695 2-s2.0-84871923836 10.1007/s00264-012-1712-5 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84871923836&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/48276
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
description Purpose: The aims of this anatomical study were to evaluate the feasibility of minimally invasive plate osteosynthesis (MIPO) using a posterolateral approach in distal tibial fractures and to study the relationship between neurovascular structures and the plate. Methods: Two separate incisions, one proximal and one distal, were made on the posterolateral aspect of ten cadaveric legs in the prone position. A 14-hole contralateral anterolateral distal tibial locking plate was inserted into the submuscular tunnel using a posterolateral approach, and one screw was fixed on each side of the proximal and distal tibia. The MIPO tunnel was then explored to identify the relationship between neurovascular bundles and plate. Results: For the proximal incision, retraction of the flexor hallucis longus and the tibialis posterior muscles medially was very important because it could protect the posterior tibial artery and the tibial nerve during plating. The sural nerve and lesser saphenous vein were easily identified and retracted in the superficial layer of the distal incision. In addition, we achieved satisfactory outcomes after using this MIPO technique in one patient. Conclusion: Based on the results of our study, it seems that using the MIPO technique through a posterolateral approach should be a reasonable and safe treatment option for distal tibial fractures, especially when the anterior soft tissue is compromised. However, studies with a higher level of evidence should be done in more patients to confirm the clinical safety of using this technique. © 2012 Springer-Verlag Berlin Heidelberg.
format Journal
author Apipop Kritsaneephaiboon
Tanawat Vaseenon
Boonsin Tangtrakulwanich
spellingShingle Apipop Kritsaneephaiboon
Tanawat Vaseenon
Boonsin Tangtrakulwanich
Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
author_facet Apipop Kritsaneephaiboon
Tanawat Vaseenon
Boonsin Tangtrakulwanich
author_sort Apipop Kritsaneephaiboon
title Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
title_short Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
title_full Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
title_fullStr Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
title_full_unstemmed Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: A cadaveric study and preliminary report
title_sort minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84871923836&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48276
_version_ 1681423219315179520