Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample

© 2017 A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid–base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base...

Full description

Saved in:
Bibliographic Details
Main Authors: Sam ang Supharoek, Kraingkrai Ponhong, Watsaka Siriangkhawut, Kate Grudpan
Format: Journal
Published: 2018
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023175026&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48434
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-48434
record_format dspace
spelling th-cmuir.6653943832-484342018-06-18T08:56:39Z Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample Sam ang Supharoek Kraingkrai Ponhong Watsaka Siriangkhawut Kate Grudpan Agricultural and Biological Sciences © 2017 A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid–base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0–5.0 mmol/L acetic acid with r 2 = 0.9925. Relative standard deviations (RSD) at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7), with limit of detection (LOD) and limit of quantification (LOQ) at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method. 2018-04-25T10:12:22Z 2018-04-25T10:12:22Z 2018-04-01 Journal 10219498 2-s2.0-85023175026 10.1016/j.jfda.2017.06.007 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023175026&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/48434
institution Chiang Mai University
building Chiang Mai University Library
country Thailand
collection CMU Intellectual Repository
topic Agricultural and Biological Sciences
spellingShingle Agricultural and Biological Sciences
Sam ang Supharoek
Kraingkrai Ponhong
Watsaka Siriangkhawut
Kate Grudpan
Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
description © 2017 A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid–base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0–5.0 mmol/L acetic acid with r 2 = 0.9925. Relative standard deviations (RSD) at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7), with limit of detection (LOD) and limit of quantification (LOQ) at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method.
format Journal
author Sam ang Supharoek
Kraingkrai Ponhong
Watsaka Siriangkhawut
Kate Grudpan
author_facet Sam ang Supharoek
Kraingkrai Ponhong
Watsaka Siriangkhawut
Kate Grudpan
author_sort Sam ang Supharoek
title Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
title_short Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
title_full Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
title_fullStr Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
title_full_unstemmed Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
title_sort employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample
publishDate 2018
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85023175026&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/48434
_version_ 1681423248356540416